Before going to the USE section:
Check around area for flammables, especially
gasoline or other vapors which may ignite. The
exhaust and top of the unit will get HOT! Make sure
there are no foreign objects around the unit or have
fallen into the top.
1. Turn on incoming water supply.
have adequate water pressure of between 20-80 PSI
(1.38~5.5 bar)
2. Turn shower nozzle to its off position
3. Turn the gas valve on the cylinder all the way open
4. IF THE SMELL OF GAS IS DETECTED, TURN OFF
THE GAS VALVE IMMEDIATELY!!!! DO NOT TOUCH
THE "ON/OFF" SWITCH
5.
Set the water regulator knob on the face of the unit
to its highest setting - All the way to the left
6. Set the gas regulator knob on the face of the unit to
the half way mark
7. Turn the "ON/OFF" switch on the bottom of the unit
to "ON" (the ON/OFF switch uses the international
standard of "I" for ON and "0" for OFF)
8
USE
Starting
Ensure that you