You can perform a hardware default in the following circumstances:
• Replacing a SIM card
• Moving an installed 3G4000W communicator to a different location or site
• Reprogramming an incorrectly programmed 3G4000W communicator
Performing a hardware default
About this task: To perform a hardware default, complete the following steps:
1.
Turn off the power to the 3G4000W communicator.
Optional:If the 3G4000W communicator uses the backup battery, disconnect it before
2.
proceeding to Step 3.
3.
Connect the Zone 2 terminal and the PGM2 terminal using a wire.
4.
Reconnect the backup battery if included and apply DC power to 12V terminals.
5.
Wait for 20 seconds, and then turn off the power.
6.
Remove or disconnect the wire between Zone 2 and the PGM 2 terminal.
SMS command and control
You can use the SMS command and control feature to send SMS text messages to the 3G4000W to
control a limited number of panel commands. The SMS command and control feature supports the
following commands:
• Arming the security panel
• Disarming the security panel
• Activating programmable outputs
• Deactivating programmable outputs
• Status request
• Help
A user sends a text message that contains the command and an access code to the 3G4000W SIM
phone number. The communicator then sends an SMS message back to the user's phone that
indicates if the function is successful or unsuccessful.
Note: To use the SMS command and control feature, you must programme the 3G4000W with
the user's mobile phone number. You can add up to six different user mobile phone numbers.
For more information on programming mobile phone numbers, see sections [332] - [337] in
the
Communicator options
The SMS command and control feature supports the following languages:
• English
• French
3G4000W 3G (HSPA) WIRELESS ALARM COMMUNICATOR INSTALLATION MANUAL 5.0
tab.
19