Receiver 1 Encrypted: All central station data packets are encrypted if the central station receiver
has encryption enabled for the communicator's account. This status indicates if the receiver 1
communications path is using encryption or not.
Receiver 2 Initialization Status: This status shows if the product is programmed to communicate
to Receiver 2 and if the product is in the process of initializing the central station receiver for the
account, if the initialization step has failed, or if the receiver was successfully initialized.
Receiver 2 Encrypted: All central station data packets are encrypted if the central station receiver
has encryption enabled for the communicator's account. This status indicates if the receiver 2
communications path is using encryption or not.
Receiver 3 Initialization Status: If the product is programmed to communicate to Receiver 3,
this status shows if the product is in the process of initializing the central station receiver for the
account, if the initialization step has failed, or if the receiver was successfully initialized.
Receiver 3 Encrypted: All central station data packets are encrypted if the central station receiver
has encryption enabled for the communicator's account. This status indicates if the receiver 3
communications path is using encryption or not.
Receiver 4 Initialization Status: If the product is programmed to communicate to Receiver 4,
this status shows if the product is in the process of initializing the central station receiver for the
account, if the initialization step has failed, or if the receiver was successfully initialized.
Receiver 4 Encrypted: All central station data packets are encrypted if the central station receiver
has encryption enabled for the communicator's account. This status indicates if the receiver 4
communications path is using encryption or not.
Zone Input 1 Status: This status shows whether the zone 1 input is in a violated or alarm state or is
restored.
Zone Input 2 Status: This status shows whether the zone 2 input is in a violated or alarm state or is
restored.
PGM Output 1 Status: This status shows whether the PGM 1 output is on or off.
PGM Output 2 Status: This status shows whether the PGM 2 output is on or off.
Communications Format: The communicator supports communications using Contact ID or SIA
formats. There is a setting to specify which format the communicator uses for reporting its trouble
or test transmission events. The security panel communication format is automatically detected by
the communicator and identified.
Cellular Network Provider: This field indicates if the network provider can be detected. For
example: Movistar, Entel.
Cellular Network Type: This status indicates whether 2G or 3G technology is being utilized to
connect to the cellular network.
Cellular Network CSQ: The CSQ relates to the product's effective signal strength, ranging from 0
(no signal) to 31.
FTC Trouble: This status indicates if a failure to communicate trouble is present.
Low Battery Trouble: This status indicates that the battery voltage is low and requires a charge.
Battery Absent Trouble: This status indicates that the battery is not connected. If no battery is
used, a programmable option exists to disable battery monitoring.
Insufficient Signal Strength Trouble: This status indicates that the radio's signal strength has
fallen below 4 CSQ (-105 dBm).
Radio Initialization Trouble: This status indicates that the radio could not be activated properly
and has failed to initialize.
Cellular Service Not Available Trouble: This condition is not supported in 3G4000W
3G4000W 3G (HSPA) WIRELESS ALARM COMMUNICATOR INSTALLATION MANUAL 5.0
23