3.
To electrically connect the communicator to the panel, perform the following steps (See
a.
Disconnect both AC power and battery connections from the panel, and disconnect telephone line.
b.
Confirm that the SIM card is inserted in the holder and locked.
4.
Install Network Cable (TLXXXX models only). Route the CAT 5 Ethernet cable through back of the panel and plug it
into the communicator's RJ45 jack.
NOTE: Before leaving the premises the Ethernet communication lines must first be connected to an approved (acceptable
to local authorities) type NID. All wiring shall be performed according to the local electrical codes.
HS2016/2032/2064/2128
UA621
5
AC AC
AUX+
Item
Description
1
To External Antenna
AUDIO / DEFAULT
2
Jumper pins 4 and 5 to reset
3
Network Link - Yellow
From NID use only CAT5 supervised
4
maximum cable length 100m (328 feet)
5
RS-232 to third party device
6
RED Wire
5.
Install the RS-232 connections (R models only). If using the communicator with a 3rd party device, wire the con-
nections as per the table below:
Figure 3: Communicator Wiring Diagram
PCLINK_2
PGM1
PGM3
Z1 COM Z2 Z3 COM Z4 Z5 COM
PGM2
PGM4
1
L
SIM
o
c
3G/LTE Radio
k
TL2803G(R)E
DSC
3G2080(R)E
UA685
TL280(R)E
TL280LE(R)
6
LE2080(R)
PC-LINK
Z6 Z7 COM Z8
RING
TIP
T-1
R-1
Input Ratings:
+10.8V ~ +12.5VDC
l
90mA 3G2080(R)E/120mA TL2803G(R)E standby
l
90mA 3G2080(R)E/ LE2080(R)
l
120mA TL2803G(R)E/TL280LE(R)
l
100mA TL280(R)E
l
400mA alarm
l
DSC Panel minimum power requirements:
16.5 VAC 40 VA transformer
l
12 VDC 7Ah battery
l
9
Figure 3
):
2
1
AUDIO/DEFAULT
RJ-45
COM
3
4

Publicité