Les langues disponibles

Trouble
Trouble
indication
Indicator Digit
Yellow LED
08
– 8 Flashes
Yellow LED -
09
9 Flashes
Yellow LED
0C
– 12 Flashes
All LEDs
flashing
N/A
together
Red and
Yellow LEDs
N/A
flashing
together
Only Green
LEDs
N/A
flashing
Green LEDs
N/A
alternating
Possible
Causes
Receiver
This trouble is indicated when supervision is enabled and the unit
l
Supervision
is not able to successfully communicate with the receiver.
If this trouble persists, contact the central station.
Trouble
l
The unit has exhausted all communications attempts to all
l
FTC Trouble
programmed receivers for events generated by the communicator.
Restart the system, if trouble persists, contact the dealer.
l
This indication appears when section [021] system account code
l
Module
or sections [101], [111], [201], and [211] receiver account code
Configuration
have not been programmed. Ensure that a valid account code has
Trouble
been entered in these sections.
Boot Loader
Disconnect power, then reconnect power to the communicator
l
module.
Failed
The unit is still initializing, please wait while the unit gets its
l
Initialization
programming and establishes a connection to all programmed
Sequence
receivers.
NOTE: This process may take several minutes to complete.
Hardware Default
The hardware default jumper is installed and must be removed.
l
See Figure 3.
Jumper
Radio Reset or
If this status persists and the yellow LED shows 5 flashes, confirm
l
Radio
that the SIM card is active.
Initialization
Trouble Possible Solution