DSC TL280LE Guide D'installation page 5

Masquer les pouces Voir aussi pour TL280LE:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

For EN50131- 1 compliant installations, the following programming options shall be set as described. Supervision Heart-
beat (required for ATS4 and ATS5):
[851][004]
set to 0087h (135s heartbeat).
l
NOTE: The compatible receiver at ARC location shall have supervision window programmed for 1800s (ATS4) or 180s
(ATS5).
[851][005]
options 1, 2 and 3 shall be enabled.
l
[851][005]
option 8 shall be enabled.
l
Test transmission (required for ATS3):
[851]
System Test options [026-029] shall be enabled (FF) for the communication paths available.
l
[851][124-125]
and
l
test transmission cycle
Configuration of communication paths (all ATS classes)
[300][001]
select option 02 for auto routing (this will allow transmission of the events over all available communication
l
paths in the system)
[380]
enable option 5 (YES) for parallel transmission over all available communication paths (if redundant con-
l
figuration is desired)
[382]
enable option 5 (YES) to enable Alternate communicator
l
[384]
enable the desired back-up configuration (receiver 2 back-up for receiver 1 or receiver 3 back-up for receiver 1).
l
Model
Power Supply Ratings
Input Voltage
Current Consumption
Standby Current
Alarm (Transmitting)
Current
Operating Frequency
Typical Antenna Gain
Environmental Specifications
Operating Temperature
Humidity
Mechanical Specifications
Board Dimensions (mm)
Weight (grams) with
bracket
EN50131-1 Installation Requirements
[224-225]
shall be programmed with time of day for test transmission and 1440 minutes (24h) for
Ratings Compatibility
Table 1: Communicator Ratings
3G2080(R)E/LE2080(R)
Cellular only
Power is supplied from the panel's PC-Link header or a PCL-422 module in
remote cabinet installations. In remote cabinet installations, the PCL-422 module
located with the communicator is powered by either an HSM2204 or an HSM2300.
Refer to the PCL-422 installation instructions for details.
90mA
850MHz, 900MHz, 1800MHz, 1900MHz, 2100MHz
100 × 150 × 15
310
TL280(R)E
Internet only
10.8-12.5 VDC
100mA
400mA
2dBi
-10°C to 55°C (0°C to 49°C for UL/ULC)
5% ~ 93% relative humidity, non-condensing
100 x 150 x 15
300
5
TL2803G(R)E/TL280LE(R)
Internet and Cellular
120mA
100 × 150 × 15
320