Napoleon IR3N-1 Instructions D'installation Et D'utilisation page 32

Masquer les pouces Voir aussi pour IR3N-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

32
SYMPTOM
Exhaust fumes
EN
smelled in room,
headaches.
Pilot will not light.
Makes noise with
no spark at pilot
burner.
No pilot ignition (5
second continuous
beep).
Pilot sparks but will
not light.
Continues to spark
and pilot lights, but
main burner will not
light.
Appliance won't
perform any
functions.
W415-1342 / A / 03.08.17
PROBLEM
Appliance is spilling.
Wiring.
Loose connection.
Igniter Spark gap is
incorrect.
No signal from remote with
no pilot ignition.
Switch is in "OFF" position
on the valve.
Wiring is loose.
Receiver
Wire connector pins are
bent.
Valve wiring is damaged.
Gas supply.
Out of propane gas.
Pilot supply line may
contain air.
Valve.
Receiver
Incorrect wiring of
thermocouple
Short or loose connection
in sensor rod.
Thermocouple or
connections are damaged
No power to the system.
Transmitter isn't
operational.
TEST SOLUTION
-
Check door seal.
-
Check for exhaust damage.
-
Check that venting is installed correctly.
-
Room is in negative pressure; increase fresh air supply.
-
Verify the wire for the ignitor are correctly connected to the
module and pilot assembly.
-
Verify no loose connections, electrical shorts in the wiring or
ground out to any metal object.
-
Spark gap of the ignitor to the pilot should be .125" (3.2mm).
-
Reprogram receiver code.
-
Replace receiver.
-
Switch to "ON" position.
-
Ensure wiring is properly secured.
-
Reset program as follows: Hold reset button on the receiver
and wait for 2 beeps. Release after second beep. Press the
small fl ame button on the remote within 20 seconds, you will
hear an additional beep (this signals that the receiver has
been successfully reset).
-
Replace receiver.
-
Straighten pins.
-
Replace valve.
-
Verify that the incoming gas line ball valve is "Open".
-
Verify that the inlet pressure reading is within acceptable
limits, inlet pressures must not exceed 14" W.C. (34.9mb).
-
Fill the tank.
-
Repeat ignition process several times or purge the pilot
supply line.
-
Check valve and replace if necessary (Careful not to
overtighen the thermocouple).
-
Check ground connection on valve and tighten screw if loose.
-
Reset program as follows: Hold reset button on the receiver
and wait for 2 beeps. Release after second beep. Press the
small fl ame button on the remote within 20 seconds, you will
hear an additional beep (this signals that the receiver has
been successfully reset).
-
Replace receiver.
-
Ensure correct polarity of wiring.
-
Verify all connections. Verify the connections from the
pilot assembly are tight; also verify these connections are not
grounding out to any metal.
-
Verify the thermocouple is clean and the wiring between it
and the valve is undamaged.
-
Verify the interruptor block is not damaged or too tight.
-
Check breaker to verify it's in the "ON" position.
-
Check battery power and battery orientation.
42.31_2

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Ir3p-1

Table des Matières