Rating Plate/Lighting Instruction; Location - Napoleon Acies Série Manuel D'installation

Masquer les pouces Voir aussi pour Acies Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1.3
rating plate/lighting instruction location
Both the rating plate and lighting instructions are attached to a chain located on the left side of the control
area near the valve (access side). Remove the safety barrier and the control cover to gain access to the
control area, refer to the "safety barrier
installation / removal" section for detailed removal instructions.
To replace, slide the instructions back into the control area and reinstall the safety barrier assembly.
Rating plate

location

CERTIFIED TO CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22-2016 AND ANSI Z21.50-2016 FOR VENTED DECORATIVE GAS FIREPLACES.
CERTIFIÉ SELON LES NORMES NATIONALES CANADIENNES ET AMÉRICAINES: CSA 2.22-2016 ET ANSI Z21.50-2016 POUR LES APPAREILS À GAZ VENTILÉS DÉCORATIFS.
DIRECT VENT, VENTED GAS FIREPLACES. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. THIS APPLIANCE MUST BE
INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT
ANSI Z223.1, OR CSA B149, INSTALLATION CODES.
FOR USE WITH BARRIER W565-0216.
FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
9700539 (WSL)
COLONNE D'EAU(GN)
4001658 (NAC)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
L38N
CL38N
COLONNE D'EAU (GN)
0-4500FT (0-1370m)
MAX. SUPPLY PRESSURE: 7"* W.C. (NG)
24,000 BTU/h
PRESSION D'ALIMENTATION MAX: 7"* D'UNE
18,000 BTU/h
COLONNE D'EAU (GN)
38.5%
*MAXIMUM INLET PRESSURE NOT TO EXCEED 13".
*PRESSION D'ALIMENTATION MAXIMALE NE DEVAIT PAS DÉPASSER 13".
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS APPLIANCE ONLY.
WARNING:
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER
THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS / DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES:
SIDES & BACK: PER STAND OFF SPACERS FOR FRAMING AND FINISHING MATERIALS. FOR NON-COMBUSTIBLE FRAMING AND
FINISHING MATERIALS, SEE INSTALLATION MANUAL. DESSUS, CÔTÉS & ARRIÈRE: SELON LES ESPACEURS DE DÉGAGEMENT
POUR LES MATÉRIAUX D'OSSATURE SELON LA MANUEL DE PROPRIÉTAIRE POUR LES MATÉRIAUX DE FINITION.
TOP / DESSUS
0"
RECESSED DEPTH ONE SIDED/ PROFONDEUR D'ENCASTRE UNE FACE
FLOOR / PLANCHER
0"
RECESSED DEPTH SEE THRU/ PROFONDEUR D'ENCASTRE TRAVERS
SIDES / CÔTÉS
0"
BACK / ARRIÈRE
VENT TOP / DESSUS DU CONDUIT D'ÉVENT
VENT SIDES & BOTTOM / CÔTÉS ET DESSOUS DU CONDUIT D'ÉVENT
VERTICAL VENT / CONDUIT D'ÉVENT VERTICAL
MANTEL / TABLETTE
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTALLATION MANUAL FOR GREATER
EXTENSIONS. RÉFÉRER AU MANUEL D'INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES. SEE INSTALLATION MANUAL FOR
MINIMUM AND MAXIMUM VENT LENGTHS. RÉFÉRER AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR LES LONGUEURS
D'ÉVACUATION MINIMALE ET MAXIMALE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
MAX SIZE: 8.5" X 4.75"
HOLE TO BE 0.250"Ø
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
MATERIAL:
CLASS III
A-2, PERMANENT LABEL, WATERPROOF, .010MIL VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER, CAPABLE OF WITHSTANDING A
MAXIMUM TEMPERATURE OF 175°F (79°C).
MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ AVEC CELUI. " TO BE 10 POINT ARIAL, BOLD FACE,
UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT.
BLACK LETTERING ON WHITE BACKGROUND.
SERIAL NUMBERS TO BE ASCENDING FROM L38 019817
note:
WOLF STEEL LTD.
TITLE: LABEL, RATING PLATE
L38
The rating plate must remain with the appliance at all times. It must not be removed.
REVISION:
access side
FOYER À GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE
SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE
MAISONS MOBILES ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LA
NORME DE SÉCURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24
CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE
APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ
CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES
SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. CODES. INSTALLER L'APPAREIL SELON LES
CODES OU RÈGLEMENTS LOCAUX, OU EN L'ABSENCE DE TELS RÈGLEMENTS, SELON LES
CODES D'INSTALLATION ANSI Z223.1 OU CSA-B149 EN VIGUER.
BARRIÈRE W565-0216. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE TROUVENT DANS LE
4001657 (NGZ)
MANIFOLD PRESSURE: 10 INCHES W.C.(P)
4001659 (WUSA)
PRESSION AU COLLECTEUR: 10" D'UNE
MODEL
CL38P
L38P
COLONNE D'EAU (P)
ALTITUDE / ÉLÉVATION
0-4500FT (0-1370m)
MIN SUPPLY PRESSURE: 11" W.C. (P)
INPUT / ALIMENTATION
24,000 BTU/h
PRESSION D'ALIMENTATION MIN: 11" D'UNE
21,000 BTU/h
REDUCED INPUT / ALIMENTATION RÉDUITE
COLONNE D'EAU (P)
P4
38.5%
MAX. SUPPLY PRESSURE: 13" W.C. (P)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ AVEC
CET APPAREIL. UTILISER AVEC LES PORTES VITRÉES
HOMOLOGUÉES SEULEMENT AVEC CETTE APPAREIL.
AVERTISSEMENT:
N'AJOUTEZ PAS A CET APPAREIL AUCUN MATÉRIAU DEVANT ENTRER EN CONTACT AVEC
LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL
17 15/16"
FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR
16 3/16"
INTAKE SYSTEM.
0"
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'ÉVACUATION PROPRE À NAPOLEON. RÉFÉRER AU
3"
MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATION PRÉCISE. IL EST IMPORTANT DE BIEN RÉINSTALLER ET
2"
RESCELLER L'ÉVENT APRÈS AVOIR ASSURÉ LE MAINTIEN DU SYSTÈME DE PRISE D'AIR.
1"
12" *
ELECTRICAL RATING: 115V, 60HZ. LESS THAN 12 AMPERES
SPÉCIFICATIONS ÉLECTRIQUES: 115V, 60HZ. MOINS DE 12 AMPÈRE
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE
SERIAL NUMBER/NO. DE SÉRIE:
L38
DWG#: W385-2181
DATE: 05.03.17_J.F.K.
Pilot location
KEEP BURNER AND CONTROL
COMPARTMENT CLEAN. SEE
INSTALLATION AND OPERATING
INSTRUCTIONS MANUAL.
APPLIANCE NEEDS FRESH
POUR UNE UTILISER AVEC
AIR FOR SAFE OPERATION
AND MUST BE INSTALLED
MANUEL D'INSTALLATION.
WITH ADEQUATE PROVISIONS
FOR COMBUSTION
AND VENTILATION AIR.
GARDEZ LE BRÛLEUR ET LE
COMPARTIMENT DES
CONTRÔLES PROPRES.
CONSULTEZ LE MANUEL
D'INFORMATION ET
D'INSTALLATION. PAR
MESURE DE SÉCURITÉ.
CET APPAREIL DOIT
ÊTRE ALIMENTÉE EN AIR
FRAIS ET AVEC SUFFISANT
D'AIR COMBURANTET
DE VENTILATION.
W385-2181
MAX SIZE: 8.5" X 4.75"
HOLE TO BE 0.250"Ø
MATERIAL: CLASS III A-2, PERMANENT LABEL, WATERPROOF, .010MIL VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER.
MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI. " TO BE 10 POINT ARIAL, BOLD FACE,
UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT.
BLACK LETTERING ON WHITE BACKGROUND.
SERIAL NUMBERS TO BE ASCENDING FROM LV38 301150
WOLF STEEL LTD.
TITLE: RATING PLATE
LV38
REVISION:
general information
WARNING:
CAUTION:
IMPROPER INSTALLATION,
HOT WHILE OPERATING. DO NOT TOUCH.
ADJUSTMENT, ALTERATION,
KEEP CHILDREN, CLOTHING, FURNITURE,
SERVICE OR MAINTENANCE
GASOLINE OR OTHER FLAMMABLE VAPORS
CAN CAUSE PROPERTY DAMAGE,
AWAY.
PERSONAL INJURY OR LOSS OF
AVERTISSEMENT:
LIFE. REFER TO OWNER'S
L'APPAREIL EST CHAUD PENDANT SON
MANUAL. INSTALLATION AND
FONCTIONNEMENT. LES ENFANTS, LES
SERVICE MUST BE PERFORMED
VÉTEMENTS, LES MEUBLES, L'ESSENCE ET
BY A QUALIFIED INSTALLER,
AUTRES LIQUIDES QUI ÉMETTENT DES GAZ
SERVICE AGENCY OR THE
VOLATILS INFLAMMABLES DOIVENT
GAS SUPPLIER.
ÉTRE TENUS ÉLOIGNES DE L'APPAREIL.
ATTENTION:
"This appliance is only for use with the type(s)
of gas indicated on the rating plate and may
UN INSTALLATION OU UNE
be installed in an aftermarket, permanently
MODIFICATION INAPPROPRIÉE
located, manufactured home (USA only) or
DU RÉGLAGE, DU SERVICE ET DE
mobile home, where not prohibited by local
L'ENTRETIEN POURRAIENT ÊTRE
codes. See owner's manual for details. This
LA CAUSE DE DOMMAGES À LA
appliance is supplied with a conversion kit."
PROPRIETÉ DE BLESSURES
CORPORELLES OU MÊME LA
«Cet appareil doit être utilisé uniquement
MORT. CONSULTER LE MANUEL
avec les types de gaz indiqués sur la plaque
D'INFORMATION, L'INSTALLATION
signalétique et peut être installé dans une
ET LE SERVICE DOIVENT
maison préfabriquée (É.-U. seulement) ou
ÊTRE EXECUTÉS PAR UN
mobile installée à demeure si les règlements
INSTALLATEUR QUALIFIÉ POUR
locaux le permettent. Voir la notice de
LE GAZ, UNE ENTREPRISE DE
l'utilisateur pour plus de renseignements. Une
SERVICE OU LE FOURNISSEUR
trousse de conversion est fournie avec cet
DE GAZ SEULEMENT.
appareil.»
W415-1707 / 07.04.17
EN
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN VICINITY OF THIS
OR ANY OTHER APPLIANCE.
CAUTION:
DO NOT OPERATE
THE FIREPLACE WITH THE GLASS
REMOVED, CRACKED OR BROKEN.
REPLACEMENT OF THE GLASS
SHOULD BE DONE BY A LICENSED
OR QUALIFIED PERSON.
POUR VOTRE
SÉCURITÉ:
NE PAS ENTREPOSER NI UTILISER
D'ESSENCE NI D'AUTRES VAPEURS
OU LIQUIDES INFLAMMABLES
DANS LE VOISINAGE DE CET
APPAREIL OU DE TOUT AUTRE
APPAREIL.
AVERTISSEMENT:
NE PAS
UTILISER L'APPAREIL SI LE
PANNEAU FRONTAL EN VERRE
N'EST PAS EN PLACE, EST CRAQUÉ
OU BRISÉ. CONFIEZ LE
REMPLACEMENT DU
PANNEAU À UN
TECHNICIEN
AGRÉÉ.
PAGE 2 OF 2
DWG#: W385-2106
DATE: 10.28.15_NS