RATING PLATE / LIGHTING INSTRUCTION LOCATION

EN EN
ALLOW THE APPLIANCE TO COOL BEFORE PERFORMING ANY MAINTENANCE OR CLEANING.
Both the rating plate and lighting instructions are attached to a key chain located on the left side of the
control area near the valve. Remove the front to gain access to the control area, refer to the "SAFETY
SCREEN INSTALLATION / REMOVAL" section for detailed removal instructions.
To replace, slide the instructions back into the control area and reinstall the safety screen assembly.
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate
information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
W415-1539 / B / 11.22.16
WARNING
!
WARNING:
IMPROPER INSTALLATION,
KEEP BURNER AND CONTROL
ADJUSTMENT, ALTERATION,
COMPARTMENT CLEAN. SEE
SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE,
INSTALLATION AND OPERATING
PERSONAL INJURY OR LOSS OF
INSTRUCTIONS MANUAL.
LIFE. REFER TO OWNER'S
APPLIANCE NEEDS FRESH
MANUAL. INSTALLATION AND
AIR FOR SAFE OPERATION
SERVICE MUST BE PERFORMED
AND MUST BE INSTALLED
BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE
WITH ADEQUATE PROVISIONS
GAS SUPPLIER.
FOR COMBUSTION
AND VENTILATION AIR.
ATTENTION:
UN INSTALLATION OU UNE
MODIFICATION INAPPROPRIÉE
DU RÉGLAGE, DU SERVICE ET DE
GARDEZ LE BRÛLEUR ET LE
L'ENTRETIEN POURRAIENT ÊTRE
COMPARTIMENT DES
LA CAUSE DE DOMMAGES À LA
CONTRÔLES PROPRES.
PROPRIETÉ DE BLESSURES
CONSULTEZ LE MANUEL
CORPORELLES OU MÊME LA
D'INFORMATION ET
MORT. CONSULTER LE MANUEL
D'INSTALLATION. PAR
D'INFORMATION, L'INSTALLATION
MESURE DE SÉCURITÉ.
ET LE SERVICE DOIVENT
CET APPAREIL DOIT
ÊTRE EXECUTÉS PAR UN
ÊTRE ALIMENTÉE EN AIR
INSTALLATEUR QUALIFIÉ POUR
FRAIS ET AVEC SUFFISANT
LE GAZ, UNE ENTREPRISE DE
SE DE
D'AIR COMBURANTET
SERVICE OU LE FOURNISSEUR
URNISSEUR
DE VENTILATION.
DE GAZ SEULEMENT.
ULEMEN
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIÉ CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
DIRECT VENT, VENTED GAS FIREPLACES. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. THIS APPLIANCE MUST BE
INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT
ANSI Z223.1, OR CSA B149, INSTALLATION CODES.
FOR USE WITH BARRIER W565-0216.
FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
9700539 (WSL)
COLONNE D'EAU(GN)
4001658 (NAC)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
LV38N
CLV38N
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
COLONNE D'EAU (GN)
0-4500FT (0-1370m)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
30,000 BTU/h
PRESSION D'ALIMENTATION MAX: 7" D'UNE
20,000 BTU/h
REDUCED INPUT / ALIMENTATION RÉDUITE
COLONNE D'EAU (GN)
59.5%
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING:
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS / DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES:
TOP/ DESSUS
0"
RECESSED DEPTH ONE SIDED/ PROFONDEUR D'ENCASTRÉ UNE FACE
FLOOR / PLANCHER
0"
RECESSED DEPTH SEE THRU/ PROFONDEUR D'ENCASTRÉ TRAVERS
FRAMING (NOT INCLUDING FACE MATERIAL) / OSSATURE (MATÉRIAU DE FAÇON NON COMPRIS)
SIDES / CÔTÉS
0"
BACK / ARRIÈRE
VENT TOP / DESSUS DU CONDUIT D'ÉVENT
VENT SIDES & BOTTOM / CÔTÉS ET DESSOUS DU CONDUIT D'ÉVENT
VERTICAL VENT / CONDUIT D'ÉVENT VERTICAL
MANTLE / TABLETTE
TOP, SIDES & BACK: PER STAND OFF SPACERS FOR FRAMING MATERIALS. FOR FINISHING MATERIALS
SEE OWNERS MANUAL
DESSUS, CÔTÉS & ARRIÈRE: SELON LES ESPACEURS DE DÉGAGEMENT POUR LES MATÉRIAUX D'OSSATURE SELON LA
MANUEL DE PROPRIÉTAIRE POUR LES MATÉRIAUX DE FINITION.
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION MANUAL
FOR GREATER EXTENSIONS. RÉFÉRER AU MANUEL D'INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
RÉFÉRER AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR LES LONGUEURS D'ÉVACUATION MINIMALE
ET MAXIMALE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
FOR YOUR SAFETY:
CAUTION:
DO NOT STORE OR USE GASOLINE
HOT WHILE OPERATING. DO NOT TOUCH.
KEEP CHILDREN, CLOTHING, FURNITURE,
OR OTHER FLAMMABLE VAPORS
GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN VICINITY OF THIS
AWAY.
OR ANY OTHER APPLIANCE.
AVERTISSEMENT:
CAUTION:
L'APPAREIL EST CHAUD PENDANT SON
THE FIREPLACE WITH THE GLASS
FONCTIONNEMENT. LES ENFANTS, LES
VÉTEMENTS, LES MEUBLES, L'ESSENCE ET
REMOVED, CRACKED OR BROKEN.
AUTRES LIQUIDES QUI ÉMETTENT DES GAZ
REPLACEMENT OF THE GLASS
REPL
VOLATILS INFLAMMABLES DOIVENT
SHOULD BE DONE BY A LICENSED
SHOULD
ÉTRE TENUS ÉLOIGNES DE L'APPAREIL.
OR QUALIFIED PERSON.
"This appliance is only for use with the type(s)
ype(s)
POU
POUR VOTRE
of gas indicated on the rating plate and may
and may
SÉC
SÉCURITÉ:
be installed in an aftermarket, permanently
manently
NE PAS ENTREPOS
NE PAS ENTREPOSER NI UTILISER
P
located, manufactured home (USA only) or
nly) or
D'ESSENCE NI D'AUTRES VAPEURS
D'ESSENCE NI D'AUTR
mobile home, where not prohibited by local
ocal
OU LIQUIDES INFLAMMABLES
OU LIQUIDES INFLAM
codes. See owner's manual for details. This
s
DANS LE VOISIN
DANS LE VOISINAGE DE CET
appliance is supplied with a conversion kit."
upplied
APPAREI
APPAREIL OU DE TOUT AUTRE
P
L OU D
«Cet appareil doit être utilisé uniquement
eil doit être u
avec les types de gaz indiqués sur la plaque
e gaz indiqu
AVERTISSEMENT:
A ERT
signalétique et peut être installé dans une
signalétique et peut être instal
UTILISER L'APPAREIL SI LE
maison préfabriquée (É.-U. seulement) ou
maison préfabriquée (É.-U. seulement) ou
PANNEAU FRONTAL EN VERRE
P
mobile installée à demeure si les règlements
mobile installée à demeure si les règlements
N'EST PAS EN PLACE, EST CRAQUÉ
N
OUR
locaux le permettent. Voir la notice de
e perme
oir la notice de
OU BRISÉ. CONFIEZ LE
l'utilisateur pour plus de renseignements. U
l'utilisateur pour plus de renseignements. Une
REMPLACEMENT DU
PANNEAU À UN
trousse de conversion est fournie ave
trousse de conversion est fournie avec cet
TECHNICIEN
appareil.»
FOYER À GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE
SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE
MAISONS MOBILES ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LA
NORME DE SÉCURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24
CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE
APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ
CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES
SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. CODES. INSTALLER L'APPAREIL SELON LES
CODES OU RÈGLEMENTS LOCAUX, OU EN L'ABSENCE DE TELS RÈGLEMENTS, SELON LES
CODES D'INSTALLATION ANSI Z223.1 OU CSA-B149 EN VIGUER.
BARRIÈRE W565-0216. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE TROUVENT DANS LE
4001657 (NGZ)
4001659 (WUSA)
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
MODEL
CLV38P
LV38P
COLONNE D'EAU (P)
ALTITUDE / ÉLÉVATION
0-4500FT (0-1370m)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
INPUT / ALIMENTATION
30,000 BTU/h
PRESSION D'ALIMENTATION MIN: 11" D'UNE
25,000 BTU/h
COLONNE D'EAU (P)
59.5%
P4
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ
AVEC CET APPAREIL. UTILISER AVEC LES PORTES
VITRÉES HOMOLOGUÉES SEULEMENT AVEC CETTE UNITÉ.
20.5"
17.25"
AVERTISSEMENT:
N'AJOUTEZ PAS À CET APPAREIL AUCUN MATÉRIAU DEVANT ENTRER EN CONTACT
AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
0"
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION
3"
MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
2"
VENT-AIR INTAKE SYSTEM. /
1"
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'ÉVACUATION PROPRE À NAPOLEON. RÉFÉRER AU
18" *
MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATION PRÉCISE. IL EST IMPORTANT DE BIEN RÉINSTALLER
ET RESCELLER L'ÉVENT APRÉS AVOIR ASSURÉ LE MAINTIEN DU SYSTÉME DE PRISE D'AIR.
ELECTRICAL RATING: 115V, 60HZ. LESS THAN 12 AMPERES
SPÉCIFICATIONS ÉLECTRIQUES: 115V, 60HZ. MOINS DE 12 AMPÈRES
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE
SERIAL NUMBER/NO. DE SÉRIE:
LV38
DO NOT OPERATE
AP
APPAREIL.
NE PAS
AGRÉÉ.
POUR UNE UTILISER AVEC
MANUEL D'INSTALLATION.
W385-2106