7. Working life
7.8 Settings table (configuration)
All the settings which you can perform on drives are described in the following table.
Code
Determine the addresses of the connected drives:
0 = Off (if the drive is used individually)
113
1 = Master (address of the first drive)
2-8 = Slave (address of the other connected drives)
123
Set the number of slave controls in the bus system.
Set the base height of the retracted drive. The display on the hand switch then shows the base
133
height.
Parameter 213 must be switched from percentage to milimetre display prior to this.
Start initialisation: start initialisation run without having previously disconnected the mains plug of
211
the drive.
Height indication in the display:
Setting = 0 -> Height is displayed in the display in percent ("xxxP.").
213
Stroke length in mm -> Display shows the stroke moved.
If parameter 133 has a base height set, the hand switch display shows the total of the base height
and the stroke moved.
Activation of the load resistor (only with
Switching the load resistor on or off with interconnected controllers.
To ensure faultless communication between multiple controllers in one bus network, the first and
233
last controller must be defined with a load resistance.
By pressing the UP and DOWN buttons, the following values can be set:
0 = off (load resistor deactivated)
1 = on (load resistor activated)
Change the position of the decimal point of the height display. By pressing the UP and DOWN but-
tons, the decimal point can be shifted to the left or to the right:
.xxxx
x.xxx
311
xx.xx
xxx.x
xxxx.
xxxx
70
Description
RKMultiControl
quadro):