9.9
FILTERS
The furnace must not be operated without fi lters. In order to effi ciently and safely operate a slow combustion
heating system, you have to ensure a regular maintenance. This means that the chimney, the joints and the
fl ue must be kept in good condition and the air fi lters must be replaced regularly; use standard capacity pleated
air fi lters (16" x 25" x 1") (406mm x 635mm x 25mm).
9.10 BLOWER MOTOR LUBRICATION
For routine maintenance and improved bearing life, the two motor bearings can be lubricated with non
detergent SAE 20 oil every 12 months.
DO NOT OVER LUBRICATE
9.11 DOOR GASKET MAINTENANCE
It is important to maintain the door gasket in good condition. After a while, the gasket might sag; requiring
replacement.
9.12 CARE OF GLASS (IF EQUIPPED)
If the glass is not kept clean permanent discolouration and / or
blemishes may result. Normally a hot fi re will clean the glass.
The most common reasons for dirty glass include: not using
suffi cient fuel to get the appliance thoroughly hot, using green
or wet wood, closing the draft so far that there is insuffi cient air
for complete combustion.
If it is necessary to clean the glass, buff lightly with a clean dry
cloth and non-abrasive cleaner.
DO NOT CLEAN GLASS WHEN HOT! Clean the glass after the fi rst 10 hours of operation with a
recommended appliance glass cleaner. Thereafter clean as required.
The glass is very strong but do not let burning fuel rest or fall against it and always close the door gently.
NEVER FORCE IT SHUT!
If the glass should ever crack or break while the fi re is burning, do not open the door until the fi re is out and do
not operate the appliance again until the glass has been replaced. Available from your Authorized dealer.
DO NOT SUBSTITUTE MATERIALS.
H29.1
WARNING
!
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
5.3
W415-1504 / B / 11.30.16
85