30
HMF200
EN
OIL LIMIT
HARNESS
FIGURE A -
OIL FAN/LIMIT WIRING
10
(BLACK)
11
(BLUE)
(GREEN)
THE PRESET VALUES ON THE FAN LIMIT CONTROL MUST NOT BE CHANGED FROM THE FACTORY
ANY ADJUSTMENT TO THIS CONTROL WILL AFFECT THE OPERATING EFFICIENCY OF THE
○
Once the set point limits have been confi rmed, carefully manipulate the wiring inside the oil limit connec-
tion box so that installation of the connection box cover does not disturb or impede the mechanical set
point tabs and the rotary dial.
○
Make sure the fan switch lever is in the "AUTO" position. Please refer to "Control System - Sum-
mer Fan/Continuous Fan" section for more information.
STEP #17
Sealing the oil fl ue and mounting lower heat shield:
○
Slide the fl ue fi bre gasket over on the fl ue.
○
Slide the fl ue plate over the oil furnace fl ue pipe.
○
Secure the 5" (127mm) fl ue plate to the rear panel using hex head screws (8 pcs.).
W415-1504 / B / 11.30.16
OIL LIMIT &
FURNACE
MOUNTING
FLUE
BRACKET
BLOWER MODULE
HARNESS
LEFT HAND RA CONFIGURATION
13
(BLUE)
14
(BLUE)
JUMPER
REMOVED
FURNACE AND WILL VOID THE WARRANTY COVERAGE.
OIL
OIL
FURNACE
FLUE
RIGHT HAND RA CONFIGURATION
FIGURE B -
OIL FAN/LIMIT SET POINTS
FAN OFF SET
POINT LEVER
80°F (27°C)
CAUTION
SETTING.
OIL LIMIT &
MOUNTING
BRACKET
OIL LIMIT
HARNESS
BLOWER MODULE
HARNESS
FAN ON SET POINT LEVER
100°F (38°C)
HIGH LIMIT SET
POINT LEVER
250°F (121°C)