5.2
HYBRID HMF150/200 AS A "STAND ALONE" WOOD FURNACE
REQUIRED COMPONENTS:
• HMF150/200 Hybrid Furnace
• HMFK-BMP50-1 Blower Box Module
• HMFK-SOLID or HMFK-GLASS Door Kit
STEPS: Completely assemble HMF150/200 in required left or right hand "RA" confi guration as required.
STEP #1 - #4
Follow Steps 1 to 4 from SECTION 5.1 - HYBRID
HMF150/200 AS A "ADD ON" TO EXISTING FURNACE.
STEP #5
○
Locate and level the HMF150/200 while maintain-
ing a minimum 1.25" (32mm) clearance space
between the bottom of the furnace and fl oor.
○
Use levelling the legs to compensate for uneven
fl oor and snug lock nuts up to the furnace base to
prevent movement through vibration.
○
Remove the contents of the blower module kit
and compare with the contents list on the "Manu-
al" addendum, accompanying the Blower Module.
○
Remove the shipping bracket from the blower.
STEP #6
○
Place the blower box module with the blower
outlet side facing the rectangular opening on the
side panel.
○
Adjust the levelling legs on the blower box mod-
ule so that the module is level and clearance hole
on the mounting fl anges align with pilot holes on
side of the furnace panel.
STEP #7
○
Lift the blower outlet side of blower box so mount-
ing fl ange on the bottom of blower box clears the
retaining bracket on the lower edge of the furnace
side.
○
Slide the blower box in so the lower mounting
fl ange of the blower box is contained between the
fl ange of the retaining bracket and the furnace
side.
○
Fasten the sides and top mounting fl anges of the
blower box using wildrill 1/4" hex head screws.
THE INSTALLATION OF THE WOOD FURNACE / COMBINATION WOOD FURNACE MUST BE DONE IN
ACCORDANCE WITH RULES OF AUTHORITIES HAVING JURISDICTION AND THE CAN / CSA B365-01
(R2006) STANDARD FOR SOLID FUEL BURNING APPLIANCES AND EQUIPMENT.
LEVEL LEG
DESCRIPTION
QTY
ITEM
1
1
HMF150/200 HYBRID FURNACE
HMFK-BMP50 BLOWER BOX MODULE
2
1
1/4" HEX HEAD WILDRIL SCREW
11
3
HMFK-SOLID OR HMFK-GLASS DOOR KIT
1
4
1
3
2
RETAINING FLANGE
H3.41
23
EN
LOCK NUT
4
W415-1504 / B / 11.30.16