9.2 Technical Data

Minimum suction output: 3000 m³/h
Welding fumes separation class: W3 to EN ISO 15012-1
Compressed air requirement: 6 - 8 bar, pure, clean, dry and oil-free
A-assessed sound pressure level at 1 m
max. permissible ambient temperature: +5°C to 40°C
max. permissible relative humidity: 85%
Note: Please obey the instructions on the plate as well.
Part no.: 150 2627 (CAT 2.0)
All rights over changes without prior notice and errors reserved.
KEMPER CleanAirTower 2.0 Operating instructions - EN
CleanAirTower, part no. 39 0600
Fan type: Radial fan, direct driven
max. flow: 6,000 m³/h
max. stat. pressure 2,300 Pa
Motor output: 5.5 kW
Supply voltage: 3 x 400V
Frequency: 50 Hz
Rated current: 11.0A
Duty cycle: 100%
Control voltage: 24V DC
Filter area: 60 m²
Degree of separation: ≥ 99.9%
Filter material: PTFE membrane filter
Dust class: "M" to DIN EN 60335-2-69
Cleaning method Rotating nozzle
distance:
Overall height: 3,622 mm
All-up weight: 756 kg
Fan component
Weight: 349 kg
Dimensions: max. Ø = 1,172 mm
Filter component
Weight: 267 kg
Dimensions: max. Ø = 1,070 mm
Suction component
Weight: 140 kg
Dimensions: max. Ø = 1,070 mm
(pressurised air quality, class 2:4:2 in
accordance with ISO 8573-1)
L
< 72 dB(A)
pa
Height = 1,463 mm
Height = 1,502 mm
Height = 657 mm
- 77 -
Rev.: 00
Issue: 02/2017