SERVICE INSTRUCTIONS

WARNING!
appliance, make sure the appliance is OFF and the PLUG IS REMOVED
FROM THE OUTLET/POWER SOURCE!
Some parts of the Vacuum Sealer
may need replacing after repeated
use. A Maintenance Kit (Sold
Separately) (Figure 16) may be
necessary for the Vacuum Sealer to
properly function. NOTE: Remove
the inner foam oval from all of the
foam Chamber Seals. The foam oval
can be discarded, only the outer foam ring
is needed (Figure 16a).
REPLACING THE VACUUM
CHAMBER SEAL:
1. Press the ON/OFF Button on the Control
Panel to turn the Vacuum Sealer "OFF".
2. Disconnect the Vacuum Sealer from the power
supply.
3. Make sure the Vacuum Sealer is completely cool.
4. Press both of the Lid Release Buttons on each side
of the Vacuum Sealer to release the lid lock, then lift the
Vacuum Lid to open.
5. Remove the Vacuum
Chamber Seal (NOTE:
The Vacuum Chamber
Seal DOES NOT have
an adhesive backing.)
(FIGURE 17) from the
groove around the
Vacuum Chamber on
the base of the Vacuum
Sealer.
6. Position a new
Vacuum Chamber Seal
into the groove around
the Vacuum Chamber on
the base of the Vacuum
Sealer.
7. Work the Vacuum
Chamber Seal into the
groove until the seal is
completely in place.
14
Before cleaning, assembling or disassembling the
Vacuum
Chamber
Seal
Seal Bar
Heating
Element/
Seal Bar
Tape
FIGURE 16
Vacuum Sealer
Maintenance Kit
FIGURE 16A
Discard
foam
ovals
Keep
Chamber
Seals
FIGURE 17