Electrical Equipment; Preliminary Warnings - GiBiDi SL Série Mode D'emploi

Masquer les pouces Voir aussi pour SL Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SL

ELECTRICAL EQUIPMENT

1- Gearmotor; 220-230V power supply, 3x1.5mm² cable (comply with the current standards)
2- Photocell transmitter 2x0.5mm² cable
3- Photocell receiver 4x0.5 mm² cable
4- Antenna screened coaxial cable.
5- Frame 4x0.5mm² cable
6- Rack
7- Key selector 3x0.5mm² cable
8- Flashing light signaller 2x0.75mm² cable
9- Omnipolar magnetothermal switch with minimum contact opening of 3 mm Power supply line to the control unit
220-230V, 50-60Hz, 3x1.5 mm² cable (comply with the current standards).
ELECTRICAL EQUIPMENT
Operator
Type
Supply voltage
Power absorbed
Current absorbed
Thermal cuout
Pick-up capacitor
Max speed
Max torque
Operating temperature
Degree of protection
Max leaf weight
Operating frequency (%)
Type of oil / grease
Formula to calculate the
operating frequency
[28]

PRELIMINARY WARNINGS

Check that the gate structure is in conformity with the regulations in force and that leaf movement is linear without
friction.
Preliminary checks:
check that the gate structure is sufficiently robust. In any case, check that the weight and dimensions of the gate
Ÿ
fall within the limits of use of the operator;
check that the leaf can be moved manually without force (points of greatest friction) for the entire travel of the gate
Ÿ
during both opening and closing;
Irreversible electromechanical gearmotor
A + C
%Fu =
x 100
A + C + P
SL 820-830-840
220/230V 50-60Hz
MAX 350W
MAX 1.5A
140°C
10µF
0,16 m/s
20 Nm
-20°C + 60°C
IP 45
800 Kg
60% (a 20°C)
GBD PH-02
A = Opening time
C = Closing time
P = Overall pause time
A+C+P = Time between two openings
13
UK

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sl800Sl820Sl830Sl840

Table des Matières