6.2. Wheel balancer parameter configuration
Modifications to factory settings normally are not
required. However, if necessary, the machine sta-
tus and/or the operating mode can be modified.
Each parameter can be modified using the arrow
keys
The parameters that can be modified are:
1. Language:
-
to set the preferred language
2. Clock:
-
to set the current time
3. Year:
-
to set the current year
4. Month:
-
to set the current month
5. Day:
-
to set the current date
6. Timeout screensaver:
-
to set the waiting time before the main logo is
displayed
7. Radial runout threshold (1st harmonic):
-
to set the threshold that displays the measured
value in red
8. Radial runout threshold peak-to-peak:
-
to set the threshold that displays the measured
value in red
9. Lateral runout threshold (1st harmonic):
-
to set the threshold that displays the measured
value in red
10. Lateral runout threshold peak-to-peak:
-
to set the threshold that displays the measured
value in red
11. Tread height threshold:
-
to set the threshold that displays the measured
value in red
12. Wheel side slip threshold:
-
to set the threshold that displays the measured
value in red
13. RUNOUT warning:
-
enables automatic measurement of the radial
run-out of the wheel assembly or rim during
72
.
the measurement cycle (YES enabled – NO
disabled)
14. OPT warning:
-
to display the alarm indicator light in the main
working screen (YES enabled – NO disabled)
15. Disable laser:
-
to disable the lasers when faulty. If disabled,
the dimensions must be set manually and the
weights applied in the 12 o'clock position
16. Automatic position search (RPA):
-
to enable automatic position search at the end
of the spin (YES enabled – NO disabled)
17. measures dimensions with release of the auto-
matic clamping system:
-
to set the automatic measurement of the dimen-
sions every time the automatic clamping system
is activated (YES active – NO deactivated)
18. automatic outer plane selection:
-
enables automatic selection of outer balancing
plane (YES enabled – NO disabled)
19. automatic weight selection (AUTOWS):
-
configures automatic selection of balancing
programme in relation to the characteristics of
the rim (ALU1, ALU1 programme enabled - ALU2,
ALU2 programme enabled - OFF, disabled)
20. enables/disables rim search:
-
if enabled, the machine recognises automatical-
ly, during the spin with dimension acquisition,
if a complete wheel is present or only the rim
(YES active – NO deactivated).
21. 3D scanning speed
-
used to change the wheel (or only rim) spin
speed while performing a 3D scanning pro-
gramme (range from 30rpm to 70rpm).
22. 3D scanning motor step
-
used to change the motor steps while performing
a 3D scanning programme between one position
and the next (range from 1 to 5).
23. Set factory data:
-
to reset the initial machine configuration Ma-
chine calibrations are not modified.