7-3. Cleaning Filter

Tools Needed:
1
2
2
3
!
Latch filter and close door before
starting unit or operating
cleaning system.
!
Do not operate unit without filter or
with dirty filter.
!
Clean or replace filter when dirty.
!
Do not breathe the particles col-
lected by the fume extractor. Wear
approved safety equipment (respi-
rator, gloves, long sleeve shirt)
when servicing filter and spark
guard. Dispose of used element and
collected particles according to lo-
cal, state, and federal requirements.
!
If ANY air is injected into the skin or
body seek medical help immedi-
ately.
!
Read and understand the Safety
Data
Sheets
(SDSs)
manufacturer's
instructions
metals, consumables,
cleaners, and degreasers.
.
See Section 5-5 for compressed air re-
quirements for proper filter cleaning.
!
Wear protective equipment when
disconnecting compressed air sup-
ply. Internal air tank is under pres-
sure and will discharge when air
supply is disconnected.
1
Cleaning Cycle Button
Press button to operate filter cleaning sys-
tem. Clean or replace filter when Cleaning
Cycle button is flashing blue, Filter Pres-
sure gauge reading is over 4 in. w.c., or
whenever air flow is too low to extract
fumes. Keep filter latched and door closed
during cleaning to maintain a tight seal
around filter.
To clean filter, press and release Cleaning
Cycle button. The filter cleaning system op-
erates only when the unit is off.
.
Filter cleaning cycle automatically
starts every time the machine is turned
off to maximize filter life.
The system cleans the filter in about 60
seconds. Wait until the cleaning has
stopped and particles have settled before
removing particles from tray.
2
Particle Tray Release Levers
3
Particle Tray
Release latches and open door. Lift and turn
levers down to release particle tray. Pull out
tray. Remove particles from tray after every
cleaning cycle. Reinstall tray and pull levers
up to secure tray in position.
Inspect filter after cleaning (Section 7-4).
Start unit and check Filter Pressure gauge
reading.
!
Replace filter if, after cleaning, Filter
Pressure gauge reading is over 4 in.
w.c. or air flow is too low to extract
fumes.
260 905-A / 260 950-A
OM-260 545 Page 25