Extraction Arm Specifications; Fume Capture Zone - Miller FILTAIR Capture 5 Mode D'emploi

Table des Matières

Publicité

4-4. Extraction Arm Specifications

Model
XD-10
XD-12

4-5. Fume Capture Zone

Capture Zone Air Flow And Pressure Differential
OM-260 545 Page 14
Arm Reach
10 ft (3 m)
12 ft (3.7 m)
5 ft. (1.5 m)
Maximum
Fume Extraction
Zone
4 ft. (1.2 m)
Air Flow
Positive Pressure
High Negative Pressure
Arm Diameter
10 in. (254 mm)
10 in. (254 mm)
The fume capture zone repres-
ents the maximum size and
shape of the fume withdrawal
area in normal conditions (open
room with no air movement) and
with air control knob in max po-
sition.
The actual fume capture zone
may be smaller than that shown.
.
Improper placement of the
extraction arm may affect
shielding gas in the weld
zone and negatively impact
weld quality.
260 889-A

Publicité

Table des Matières
loading

Table des Matières