9
Technical data
Oval gear meter type:
Article-No.
(EBS-No.)
Article-No.
(EBS-No.)
Recommended for metering pump
Flow rate with use of an EMP
metering pump [l/h]
Flow rate (continuous flow) [l/h]
Pulse rate for connection to
higher-level control system
(e.g. PLC)**
Pulse rate for connection to E60
(electronic) (high-resolution)
Allowable system pressure [bar] max.
Ambient / fluid temperature [°C]
Viscosity [mPas]
Accuracy
Not calibrated (as delivered condition)
calibrated under service conditions
Connecting thread
* A minimum flow of 1 l/h is necessary for controller operation with E60+
electronic.
** The unit can also be programmed to other pulse sequences within the
processing limits.
9.1
Materials
Housing
Housing cover
O-ring seals
Oval gear wheels
Oval gear spindles
00112
280141
10200631
280151
10200632
EMP II/KKS
(0,9...11,2l/h)
min.
0,5*
max.
13,5
min.
1,25
max.
34
ml/Imp
1
ml/Imp
0,01
max.
max.
G1/8"
PVC, gray or PP (280048)
PVC (transparent) or PP (280048)
FPM (Viton B) optional EPDM
PVDF (for type 00112), PVC (for type 00112)
PEEK (for typs 00540, 01200, 02100, 04500)
Ceramic
41
00540
01200
280043
280044
10092943
10013357
280073
280074
10200627
10200628
EMP III
EMP III
(16...54l/h)
(80...120l/h)
(140...210l/h)
4,8
18
65
144
12
45
160
360
5
10
0,029
0,055
10
40
1000
± 5 %
± 1%
G1/4"
G3/4" *
417102208 Rev. 8-11.2019
Technical data
02100
04500
280045
280046
1010057
10106904
2
280077
280078
1020063
10200629
0
EMP IV
EMP IV
(450l/h)
40
60
250
540
100
150
625
1200
20
50
0,133
0,222
G1 1/4"