Installation
5.5.1

Overview

1
2
3
4
5
6
Fig. 4: Overview
1
Hose
1a Pipe
2
Union nut
3
Clamping element
5.5.2

Connection of hose

Note data on the in-pack notelet with the hose connecting elements!
Cut the hose (Fig. 4, pos. 1) at right angles.
n
n
Slip the union nut (pos. 2) and clamping element (Pos. 3) over the hose.
n
Slip the hose onto the cone (pos. 4) up to the stop collar.
n
Position the O-ring seal (pos. 5) into the groove provided on the connecting adapter
(pos. 6).
n
Connect the hose and cone (pos. 4) and tighten the union nut (pos. 2).
5.5.3

Connection of pipe

n
Cut the pipe (Fig. 4, pos. 1a) at right angles.
n
Slip the union nut (pos. 2) over the pipe.
Weld / adhesive bond the insert (pos. 3a) to the pipe.
n
n
Position the O-ring seal (pos. 5) in the groove provided on the connecting adapter
(pos. 6).
n
Tighten the union nut (pos. 2).
5.6

Electrical connection

PLUS
The OGM
Electrical connection is accomplished by means of a four-pole M12 connector.
417102208 Rev. 8-11.2019
1a
2
3a
5
6
electronic evaluation system is moulded into the cover.
3a Insert element
4
Cone
5
O-Ring
6
Connecting adapter