Troubleshooting guide

Fault
Gas mode
Boiler does not operate after
switching on.
After switching on, boiler does
not operate and red LED comes
on after about 30 sec.
After a long period of operation,
boiler switches to "Fault" and
red LED comes on.

Water supply

Water dripping from drain valve
Warm water coming out of cold
water tap
If these actions do not remedy the problem, please contact Truma Service.
12
Cause
– No 12 V
power supply
– Window open
– Cowl cover is fitted
– No gas supply
– Incorrect gas pressure
– Air in gas supply
– Overtemperature sensor
has activated
– Water pressure too high
– Hot water flowing
back into cold water supply
Remedy
– Check battery voltage (min. operating voltage 10.5 V)
– Check boiler fuse
(see Maintenance, "Fuses").
– Close window above cowl.
– Remove cowl cover and/or check for soiling and remove
if necessary.
– Check gas valves and cylinder.
– Check gas valves and cylinder.
– To clear the fault (and bleed off air), switch device off,
wait for 5 minutes and switch on again.
– Check the water content, topping up if necessary (close
drain valve).
– To clear the fault, switch device off, wait for 5 minutes
and switch on again.
– Check water pressure (max. 2.8 bar) When connecting to
a central water supply a pressure reducer must be used.
– Fit a non-return valve to the cold water supply
(see installation instructions, "Water connection").