5. WILO YONOS PARA CIRCULATOR
Led light
Meaning
Green light illuminated
Pump in operation
Green light flashing rapidly
Vent function
Red / green light flashing
The pump is ready but is not
turning
Red light flashing
Pump is not working
LED off
No Power supply
5.3 CE Declaration of conformity
of the circulator
The circulator covered in this instruction manual complies with the
following directives and standards:
– Electromagnetic Compatibility Directive 2004/108/EC;
– Low Voltage Directive 2006/95/EC;
– ErP directive 2009/125/EC
– Applied harmonised standards, namely: EN 60335-2-51,
EN 61000-3-2, EN 61000-3-3, EN 55014-1&2.
The conformity certificate is on the last page of this manual.
30
Operating state
Cause
The pump is operating accor-
Normal operation
ding to its setting
The pump is is venting for
Normal operation
10 mins. It is necessary
to set the desired power
afterwards.
The pump will begin
1. Power supply too low
operating as soon as the
U < 160 V or too high
error has been corrected
U >253 V
2. Module Temperature
too high
The pump has stopped
The pump will not restart
(blocked)
automatically
There is no power supply to
1. The pump is not connected
the electronics
to the power supply
2. The LED is defective
3. L'elettronica è difettosa
GB
GB
Remedy
1. Check the power supply
voltage: 195 V < U < 253 V
2. Check fluid and ambient
temperatures
Replace the pump
1. Check the cable connection
2. Check if the pump is
working
3. Replace the pump