Table 51:
Structure of attribute 2
Byte
Bit
Byte 1
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Byte 2
Bit 0 to 7
Byte 3
Bit 0 to 7
Byte 4
Bit 0 to 7
Byte 5
Bit 0 to 7
Byte 6
Bit 0 to 7
Byte 7
Bit 0 to 1
Bit 2 to 7
Table 52:
Common services
Service code
Class
0x0E
x
0x10
–
AVENTICS | Bus Coupler AES/Valve Driver AV, DeviceNet | R412018138–BAL–001–AC
Meaning
The backplane of the valve zone issues
a warning.
The backplane of the valve zone issues
an error.
The backplane of the valve zone attempts
a re-initialization.
Reserved
The backplane of the I/O zone issues
a warning.
The backplane of the I/O zone issues an error.
The backplane of the I/O zone attempts
a re-initialization.
Reserved
Group diagnosis, module 1 to 8
Group diagnosis, module 9 to 16
Group diagnosis, module 17 to 24
Group diagnosis, module 25 to 32
Group diagnosis, module 33 to 40
Group diagnosis, module 41 to 43
Reserved
The length of the attribute should always be 8 bytes, independent of the number of participants.
The data for attributes 1 and 2 is transparently forwarded from and to the AES API.
Instance
x
x
Type of diagnosis and diagnostic
device
Bus coupler diagnosis
Group diagnoses of modules
Group diagnoses of modules
Group diagnoses of modules
Group diagnoses of modules
Group diagnoses of modules
Group diagnoses of modules
Service name
Description of service
Get_Attribute_Single
Returns the contents
of the specified attribute.
Set_Attribute_Single
Used to modify a DeviceNet
object attribute value.
133
Appendix