Ua-Off Monitoring Board; Possible Combinations Of Base Plates And Cards; Identifying The Modules; Material Number For Bus Coupler - Aventics DeviceNet Description Du Système Et Notice D'emploi

Coupleur de bus aes / pilote de distributeur av
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 137
112
AVENTICS | Bus Coupler AES/Valve Driver AV, DeviceNet | R412018138–BAL–001–AC
Conversion of the Valve System
12
Bridge cards are available in long and short versions:
The long bridge card is always located directly on the bus coupler. It bridges the transition plate and
the first pneumatic supply plate.
The short bridge card is used to bridge additional pneumatic supply plates.
12.2.8

UA-OFF monitoring board

The UA-OFF monitoring board is an alternative to the short bridge card in the pneumatic supply plate
(see Fig. 15 on page 111).
The electrical UA-OFF monitoring board monitors the actuator voltage UA for status UA < UA-OFF.
All voltages are directly passed through. The UA-OFF monitoring board must therefore always
be installed after an electrical supply plate to be monitored.
In contrast to the bridge card, the UA-OFF monitoring board has to be taken into account when
configuring the control.
12.2.9

Possible combinations of base plates and cards

Valve driver boards, 4x, are always combined with two 2x base plates. Table 24 shows the possible
combinations of base plates, pneumatic supply plates, electrical supply plates, and transition plates
with various valve driver boards, bridge cards, and supply boards.
Table 24:
Possible combinations of plates and cards
Base plate
Base plate, 2x
Base plate, 3x
Two base plates, 2x
Pneumatic supply plate
Transition plate and pneumatic supply plate
Electrical supply plate
1)
Two base plates are linked with a valve driver board.
The boards in the AV-EP base plates are installed permanently and can therefore not
be combined with other base plates.

12.3 Identifying the modules

12.3.1

Material number for bus coupler

The bus coupler can be clearly identified using its material number. When exchanging the bus
coupler, you can use the material number to reorder the same unit.
The material numberMaterial number is printed on the rating plate (12) on the back of the device
and on the top below the identification key. The material numbermaterial number for the AES series
bus coupler for DeviceNet is R412018221.
Circuit boards
Valve driver board, 2x
Valve driver board, 3x
1)
Valve driver board, 4x
Short bridge card or UA-OFF monitoring board
Long bridge card
Supply board

Publicité

Table des Matières
loading

Table des Matières