108
AVENTICS | Bus Coupler AES/Valve Driver AV, DeviceNet | R412018138–BAL–001–AC
Conversion of the Valve System
Fig. 8:
Base plates, 2x and 3x
20
20
Valve position 1
Valve position 2
Valve position 3
12.2.2
Transition plate
The transition plate (29) has the sole function of mechanically connecting the bus coupler to the
valve zone. It is always located between the bus coupler and the first pneumatic supply plate.
Fig. 9:
Transition plate
12.2.3
Pneumatic supply plate
Pneumatic supply plates (30) can be used to divide the valve system into sections with different
pressure zones (see section 12.5 "Conversion of the valve zone" on page 116).
Fig. 10: Pneumatic supply plate
12.2.4
Power supply unit
The electrical supply plate (35) is connected to a supply board. It can feed in an extra 24 V power
supply for all valves located to the right of the electrical supply plate via an integrated 4-pin
M12 connection. The electrical supply plate monitors the additional power supply (UA) for low
voltage.
21
20 Base plate, 2x
21 Base plate, 3x
29
29
30
30
21
P