AVENTICS | Bus Coupler AES/Valve Driver AV, DeviceNet | R412018138–BAL–001–AC
Conversion of the Valve System
20
Fig. 12: Blocking of base plates and valve driver boards
22
37
36
Valve position 1
Valve position 2
Valve position 3
Valve position 4
The following valve driver and supply boards are present:
22
Fig. 13: Overview of the valve driver and supply boards
22 Valve driver board, 2x
23 Valve driver board, 3x
24 Valve driver board, 4x
Electrical supply plates can be used to separate the valve system into sections with different voltage
zones. For this purpose, the supply board interrupts the 24 V and the 0 V lines from UA voltage in
the backplane. A maximum of ten voltage zones are permitted.
The power supply to the electrical supply plate must be taken into account during PLC
configuration.
12.2.6
Pressure regulators
You can use electronically operated pressure regulators as a pressure zone control or single
pressure control depending on the selected base plate.
37
22
36
20 Base plate, 2x
22 Valve driver board, 2x
36 Right plug
37 Left plug
23
24
35 Electrical supply plate
38 Electrical supply board
20
38
35
UA