Wired zones 1-40 / Wired zones 41-80 / Wireless zones

Functions menu

Timer
Link
16
Icon type: Type of function you wish to add/modify.
Icon number: Enter the number of the wired or wireless zone corresponding to the programming
implemented for the alarm control panel.
Icon description: Description which will appear underneath the icon within the associated function.
Timer number: Up to 32 timers can be entered.
Timer description: Description associated with the timer.
Timer: Select if you wish to set a timer to transmit commands over the BUS in order to control
other modules or systems.
Virtual: Select if you wish to set a virtual timer to carry out actions exclusively within the set time
band. The virtual timer can then be used from the Rules menu.
Start timer / End timer: Time at which the timer will be activated or deactivated.
Enable days: Days on which the timer will be activated.
Timer enabled: Tick the option to activate the timer.
Enable zone assoc.: A zone number can be associated with a timer in order to enable or disable
the latter, for example using a button connected to the home automation bus
set as a zone command.
Recipient: Select what will be controlled by the timer.
Module + output: Select the module number, the module output number and the type of command
you wish to send.
Zone: Select the zone number and the type of command you wish to send.
Supervisor: Select the supervisor input number.
Scenario: Select the number of the scenario you wish to activate.
Sensor temp.: Select the module number, the module input number, the operating
Thermostat temp.: Select the module number, the module input number, the operating
Alarm: Select the area number and the type of command you wish to send.
The link can be used to link an anti-intrusion system event to a command sent over the home
automation bus. For example, a scenario can be implemented when the alarm is triggered in a
control unit area.
Link number: Up to 32 links can be entered.
Link type: Select the anti-intrusion system element to be linked with the home automation event.
Input / Area: Select the control unit or area input number.
Recipient: Select what will be controlled by the link.
Module + output: Select the module number, the module output number and the type of
Zone: Select the zone number and the type of command you wish to send.
Supervisor: Select the supervisor input number.
Scenario: Select the scenario number.
regime and the desired temperature.
regime and the desired temperature.
command you wish to send.