Rules
Scenarios
Network confi guration menu
The rules allow the association of up to 3 anti-intrusion system elements in order to trigger an
event that can send commands over both systems. For example, it is possible to switch on a timed
light if an alarm control unit input is opened (when a volumetric sensor enters alarm mode) only if
an alarm control unit area has been activated.
Rule number: Up to 32 rules can be entered.
Element number: Enter the number of the element included in the rule.
Element type: Enter the element to be supervised for the implementation of the rule with the
corresponding module number, area number, etc...
If you set an alarm control unit input to the status value 0, this indicates that the
zone is in standby; the value 1 indicates that the zone is in alarm mode. For a
home automation module, the status 0 indicates that the input is in standby; the
status 1 corresponds to an input that has been activated.
P.S. if you select "Bus input", the ON/OFF status of a home automation module
can be entered in the rule. This input must be set in the programming software as
a supervisor input.
Relationship: Up to 3 elements can be linked in one rule. After entering an element, select AND
or OR to move onto the next elements. Select END to enter the result of the rule.
Up to 32 scenarios can be programmed with 20 elements each, sending commands over the
automation or anti-intrusion system.
Scenario number: Select the Scenario number.
Element number: Enter the scenario element number. After programming an element, save the
confi guration and move on to the next element.
Recipient: Select what will be controlled.
Module + output: Select the module number, the module output number and the type of
command you wish to send.
Zone: Select the zone number and the type of command you wish to send.
Scenario: Select the number of the scenario you wish to activate. Several scenarios can
be linked together by adding a second scenario as an element.
Sensor temp.: Select the module number, the module input number, the operating
regime and the desired temperature.
Thermostat temp.: Select the module number, the module input number, the operating
regime and the desired temperature. If you enter a Minitouch
thermostat, etc... enter the input number as 1.
Alarm: Select the area number and the type of command you wish to send.
End: Select this option as the last command for the set scenario.
This menu can be used to confi gure all device network parameters.
CAUTION!! Incorrect settings could cause the screen to disappear.
It is important to enter valid DNS addresses in the Primary and Secondary DNS address boxes,
because it is possible to set automatic date and time updating directly through the network, via
port 123 confi gured as UDP.
It is best not to select the option "Enable DHCP", so that the Serial Bridge has a fi xed IP address
and can therefore always be reached from the network.