For cleaning machines, parts & supplies click/visit www.southeasternequipment.net
MACHINE SETUP
INSTALLING BRUSH
FOR SAFETY: Before installing brush turn the
main power switch to the off position.
1. Raise the scrub head to the transport position by
stepping on the scrub head lift pedal (Figure 1).
FIG. 1
2. Remove the brush idler plate from the brush base.
Turn the idler plate locking knob counter--clockwise
to remove (Figure 2).
FIG. 2
3. Connect the slotted end of the brush to the drive
hub (Figure 3).
FIG. 3
Tennant T1 Li (09- -10)
For cleaning machines, parts & supplies click/visit www.southeasternequipment.net
4. Connect the idler plate to the brush and reinstall
the idler plate. Make sure the idler plate tabs
engage the brush base and that the locking knob is
secure (Figure 4).
FIG. 4
NOTE: If storing the machine for an extended period,
raise the scrub head to the transport position to prevent
flat spot on brush.
FILLING SOLUTION TANK
1. Remove the solution tank and carry tank to solution
source (Figure 5).
FIG. 5
2. Fill the solution tank with 2 gallons/7.6 L of clean
water (122°F/50°C maximum temperature) . Do not
fill beyond the "MAX" fill label (Figure 6).
FIG. 6
OPERATION
EN
7