ENGLISH
OPERATION MANUAL
Off Via DMX (Turn off the unit via DMX controller)
Select Off Via DMX, press ENTER button to confirm, current mode will blink on the display, use UP and
DOWN buttons to select Yes (enable turn off lamp via DMX) or No (disable turn off lamp via DMX), press
ENTER button to store. Press the MENU button to go back to the last menu, if you leave the unit unused for
one minute it will automatically exit from menu mode.
PS: When you operate the unit via DMX controller, set the value of channel "special function" to "lamp off",
after 5 seconds the lamp will be switched off.
On If DMX On (Lamp turns on when DMX signal is detected)
Select On If DMX On, press ENTER button to confirm, current mode will blink on the display, use UP and
DOWN buttons to select Yes (Lamp turns on when DMX signal is detected) or No (keep the default setting),
press ENTER button to store. Press the MENU button to go back to the last menu, if you leave the unit
unused for one minute it will automatically exit from menu mode (If the lamp is off via DMX signal, you can
reconnect the DMX controller to switch the lamp on).
Off If DMX Off (Lamp turns off when DMX signal is off)
Select Off If DMX Off, press ENTER button to confirm, current mode will blink on the display, use UP and
DOWN buttons to select Yes (Lamp turns off when DMX signal is cut off), press ENTER button to store.
Press the MENU button to go back to the last menu, if you leave the unit unused for one minute it will
automatically exit from menu mode.
Ignition Delay (Delay time between power on and lamp on)
Select Ignition Delay, press ENTER button to confirm, current mode will blink on the display, use UP and
DOWN buttons to adjust the delay time from 0S to 255S, press ENTER button to store. Press the MENU
button to go back to the last menu, if you leave the unit unused for one minute it will automatically exit from
menu mode.
Low Power Delay (Delay time between reduce lamp power and shutting off the unit)
Select Low Power Delay, press ENTER button to confirm, current mode will blink on the display, use UP
and DOWN buttons to adjust the delay time from 0s to 255s, press ENTER button to store. Press the MENU
button to go back to the last menu, if you leave the unit unused for one minute it will automatically exit from
menu mode. (If you set the low power delay time to 3s, the lamp will run in half power 3 seconds after the
shutter is totally closed)
Display Setting
Enter menu mode, select Display Setting, press ENTER button to confirm, use UP and DOWN buttons to
select Display Inverse, Backlight Auto Off, Backlight Intensity or Temperature unit and Display
Warning.
Display Inverse
Select Display Inverse, press ENTER button to confirm, current mode will blink on the display, use UP and
DOWN buttons to select No (normal display) or Yes (inverse display), press ENTER button to store. Press
the MENU button to go back to the last menu, if you leave the unit unused for one minute it will automatically
exit from menu mode.
Backlight Auto Off
Select Backlight Auto Off, press ENTER button to confirm, current mode will blink on the display, use UP
and DOWN buttons to select No (display always on) or Yes (display goes off one minute after exiting menu
mode), press ENTER button to store. Press the MENU button to go back to the last menu, if you leave the
unit unused for one minute it will automatically exit from menu mode.
Backlight Intensity
Select Backlight Intensity, press ENTER button to confirm, current mode will blink on the display, use UP
and DOWN buttons to adjust backlight intensity from 1 (dark) to 10 (bright), press ENTER button to store.
Press the MENU button to go back to the last menu, if you leave the unit unused for one minute it will
automatically exit from menu mode.
BRITEQ
9/78
BTX-BEAM 2R
®