ero electronic LFS Manuel De Service page 32

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Calibration : according to IEC 584-1 and DIN
Calibration
Calibration
Calibration
Calibration
43710 - 1977.
STANDARD RANGES TABLE
T/C
T/C
T/C
T/C
T/C
Ranges
Ranges
Ranges
Ranges
Ranges
type
type
type
type
type
L L L L L
0
0 /+ 400.0°C
L L L L L
1
0 /+ 900 °C
19
0 / + 1650 °F
J J J J J
2
-100.0/+ 400.0°C
J J J J J
3
-100 /+ 1000 °C
20
-150 / + 1830 °F
K K K K K
4
-100.0/+ 400.0°C
K K K K K
5
-100 /+ 1370 °C
21
-150 / + 2500 °F
N N N N N
6
-100 /+ 1400 °C
22
-150 / + 2550 °F
R R R R R
7
0 /+ 1760 °C
23
0 / + 3200 °F
S S S S S
8
0 /+ 1760 °C
24
0 / + 3200 °F
T T T T T
27
-199.9/+ 400.0°C
28
-330 / + 750 °F
B) RTD (R R R R R esistance T T T T T emperature D D D D D etector)
B) RTD
B) RTD
B) RTD
B) RTD
Input: for RTD Pt 100 Ω, 3-wire connection.
Input
Input
Input
Input
Input circuit
Input circuit
Input circuit
Input circuit
Input circuit: current injection.
°C/°F selection
°C/°F selection: via front pushbuttons or serial link.
°C/°F selection
°C/°F selection
°C/°F selection
Line resistance
Line resistance
Line resistance
Line resistance
Line resistance: automatic compensation up to
20 Ω/wire with no measurable error.
Calibration
Calibration
Calibration: according to DIN 43760
Calibration
Calibration
Burnout
Burnout
Burnout: up scale. NOTE
Burnout
Burnout
NOTE
NOTE
NOTE: a special test is
NOTE
provided to signal OVERRANGE when input
resistance is less than 15 Ω.
STANDARD RANGES TABLE
Input
Input
Input
Input
Input
Ranges
Ranges
Ranges
Ranges
Ranges
type
type
type
type
type
- 199,9 / + 400,0 °C
9
RTD Pt 100
RTD Pt 100
RTD Pt 100
RTD Pt 100
RTD Pt 100 Ω Ω Ω Ω Ω
10
- 200
/ + 800
DIN 43760
DIN 43760
DIN 43760
DIN 43760
DIN 43760
25
-199,9 / +400,0 °F
-330 / + 1470
26
LFS-1-CC.P65
29
C) LINEAR INPUTS
C) LINEAR INPUTS
C) LINEAR INPUTS
C) LINEAR INPUTS
C) LINEAR INPUTS
Read-out
Read-out
Read-out: keyboard programmable between
Read-out
Read-out
-1999 and +4000.
Decimal point
Decimal point
Decimal point: programmable in any position
Decimal point
Decimal point
Burn out
Burn out
Burn out: the instrument shows the burn out
Burn out
Burn out
condition as an underrange condition for 4-20 mA, 1-
5 V and 2-10 V input types.
---
It shows the burn out condition as an underrange or
an overrange
condition (selectable by soldering
---
jumper) for 0-60 mV and 12-60 mV input types. No
indication are available for 0-20 mA, 0-5 V and 0-10
---
V input types.
Input type
Input type
Input type
Input type
Input type
impedance
impedance
impedance
impedance
impedance
11
0 - 60 mV
> 1 MΩ
12
12 - 60 mV
13
0 - 20 mA
< 5 Ω
14
4 - 20 mA
15
0 - 5 V
> 200 kΩ
16
1 - 5 V
17
0 - 10 V
> 400 kΩ
18
2 - 10 V
D) LOGIC INPUT
D) LOGIC INPUT
D) LOGIC INPUT
D) LOGIC INPUT
D) LOGIC INPUT
The instrument is equipped with one input from
contact (voltage free) for setpoint selection.
Contact open = Main setpoint.
Contact closed = Auxiliary setpoint.
N O T E S :
N O T E S :
N O T E S :
N O T E S :
N O T E S :
1) Use an external dry contact capable of
switching 0.5 mA, 5 V DC.
2) The instrument needs 100 ms to recognize a
contact status variation.
°C
3) The logic input is NOT
NOT isolated by the
NOT
NOT
NOT
measuring input.
4) This optional function is in alternative to
°F
amperometer sensing transformer input.
GB
GB
GB
GB
GB
29
13/07/2004, 14:40
Accuracy
Accuracy
Accuracy
Accuracy
Accuracy
0.2 % + 1 digit
@ 25°C

Publicité

Table des Matières
loading

Table des Matières