Pin assignments for the PROFIBUS interface are shown in Figure 2-44.
Follow the wiring instructions included with the connector to terminate the wires.

EtherNet/IP and Modbus TCP Interface

The EtherNet/IP Module (Figure 2-45) connects to the network via a standard
Ethernet patch cable. The module's address is set in software, and the DIP
switches are not used and must all be set to OFF.
Figure 2-46 shows the array of status indicator LEDs on the EtherNet/IP card.
2-28
Figure 2-43: PROFIBUS Option Board, Panel Mount Enclosure
PIN
SIGNAL
1
Not used
2
Not used
3
RxD/TxD +
4
RTS
5
GND bus
6
+5V bus
7
Not used
8
RxD/TxD -
9
Not used
Figure 2-44: PROFIBUS Nine-Pin Connector Assignments
Figure 2-45: Ethernet / IP Option Board
NOTES:
1. USE MATING CONNECTORS AND CABLE
RECOMMENDED FOR PROFIBUS CONNECTIONS.
2. REFER TO PROFIBUS INTERNATIONAL
DOCUMENTATION FOR OTHER CONSIDERATIONS.