Mettler Toledo IND560 Guide D'installation page 47

Masquer les pouces Voir aussi pour IND560:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Ethernet, COM2, and COM3 Connections
The Ethernet/TCP IP and dual COM port option board (Figure 2-27) is positioned in
the center option slot on the Main board. This port provides a 10 Base-T
connection (10 Mb) connection for Ethernet and two serial ports labeled COM2
and COM3. The Ethernet connection is made via a standard RJ45 connector on the
option board. The connector is shown in Figure 2-27.
Figure 2-27: Ethernet Connection Option Board
COM2 provides only RS-232 and should be connected as shown in Figure 2-28.
COM3 provides RS-232, RS-422 or RS-485 connections, which is identical to
COM1 on the Main board except the +5 VDC supply on the last terminal is not
provided. Refer to the COM1 connection section described previously for
instructions for wiring to this port. Review Figure 2-21 and Figure 2-22 for
additional details.
IND560 Installation Manual
NOTES:
1. USE ONLY SHIELDED CABLE.
2. MAXIMUM CABLE LENGTH: 50 FEET (15 METERS).
3. WIRE SIZE: 18 AWG (.823 mm
24 AWG (0.205 mm
Figure 2-28: Wiring to COM2
RJ45
connector
2
) MAXIMUM
2
) MINIMUM.
2-19

Publicité

Table des Matières
loading

Table des Matières