Voltage Selector Switch Location; 120 Volt Cord Plug Installation - Napoleon Ascent Electric Serie Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3.3 voltage selector switch location

WARNING
!
The voltage selector switch must match the incoming power supply voltage. The heater will overheat if the
switch does not match the incoming power supply voltage.
When changing the voltage selector switch from 240 volts to 120 volts (or vice versa), the power supply must
be turned off first.
The voltage selector switch is located inside the appliance (Fig. 1).
Remove the glass door (see "glass door removal and installation" section).
A.
Remove metal cover from the voltage selector switch.
B.
Change the voltage selector switch position.
C.
note:
Factory default setting is 120 volt (115 printed on the switch) if you use 120 volt power supply you do not
need to make the changes.
When wiring the appliance for 240 volt, the voltage selector switch should be in 230 volt position on the switch.

3.3.4 120 volt cord plug installation

The factory default setting is 120 volt cord plug installation configuration. Simply plug the appliance to a
grounded 120V 15 Amp outlet box.
note:
Must be connected to a dedicated 15 Amp circuit. The use of an extension cord is NOT permitted.