Installing Non-Combustible Board - Napoleon HD35NT-2 Instructions D'installation Et D'opération

Masquer les pouces Voir aussi pour HD35NT-2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.3

installing non-combustible board

NON-COMBUSTIBLE FINISHING MATERIAL
COMBUSTIBLE
MATERIAL
A
A
NOTE: For detailed installation instructions on the 4-sided frame, optional faceplate or bevelled trims
refer to the installation instructions provided with the kit.
A joint compound that is resistant to heat and cracking should be used when taping and mudding
seams.
NON- COMBUSTIBLE MATERIAL
FINISHING DIMENSIONS
Ref
HD35-2
A
33"
(83.8cm)
B
33 3/4"
(85.7cm)
Non-combustible Material Definitions
Material which will not ignite and burn. Materials consisting entirely of steel, iron, brick, tile, concrete, slate, glass
or plasters, or any combination thereof are suitable.
Materials that are reported as passing ASTM E 136, Standard Test Method for Behaviour of Materials in a
Vertical Tube Furnace at 750°C (1382°F) and UL763 shall be considered non-combustible materials.
COMBUSTIBLE
MATERIAL
NON-COMBUSTIBLE
MATERIAL SUCH AS TILE,
MARBLE GRANITE, ETC.
NON-COMBUSTIBLE
MATERIAL SUCH AS TILE,
MARBLE GRANITE, ETC.
7 3/8"
187mm
MIN
7 3/8"
187mm
B
MIN
B
1 1/4"
32mm
MIN
1 1/4"
32mm
MIN
HD40-2
HD46-2
38"
44"
(96.5cm)
(111.8cm)
33 3/4"
33 3/4"
(85.7cm)
(85.7cm)
COMBUSTIBLE FINISHING MATERIAL
COMBUSTIBLE
MATERIAL
COMBUSTIBLE
MATERIAL
B
A
B
A
COMBUSTIBLE MATERIAL
FINISHING DIMENSIONS
Ref
HD35-2
HD40-2
35 3/4"
40 3/4"
A
(90.8cm)
(103.5cm)
35 1/4"
40 1/4"
B
(89.5cm)
(102.2cm)
41"
41"
C
(104.1cm)
(104.1cm)
31
EN
NOTE: THREE NAILERS
ARE REQUIRED.
NOTE: THREE BRACES
NON-COMBUSTIBLE
ARE REQUIRED.
(SUPPLIED)
NON-COMBUSTIBLE
(SUPPLIED)
6 1/2"
[165mm
MIN
6 1/2"
[165mm
MIN
C
C
HD46-2
46 3/4"
(118.7cm)
46 1/4"
(117.5m)
41"
(104.1cm)
W415-2197 / A / 09.14.17