Non-Combustible Facing Material; Alcove Installation - Napoleon HD35NT-2 Instructions D'installation Et D'opération

Masquer les pouces Voir aussi pour HD35NT-2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

32
5.4

non-combustible facing material

EN
A
A
WARNING: 2" (51mm) clearance from the surround is required for any additional projecting out a
maximum 2" (51mm). If greater projections are desired, increase the clearance from the surround by 2"
(51mm) for every 1" (25mm) of additional projection.
5.5

alcove installation

NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.
Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.
The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment
can be made by increasing any or all of the height, width and depth of the enclosure.
W415-2197 / A / 09.14.17
6" (152mm)
4" (102mm)
2" (51mm)
RECESS OR
ALCOVE
AREA
ENCLOSURE
AREA
APPLIANCE
4"
(102mm)
3" (76mm)
2" (51mm)
TOP OF
APPLIANCE
0" (0mm)
SAFETY
DOOR
SCREEN
SECTION A - A
71.2