539AFB-P / 549AFB-P / 550CAP Arch Fronts Installation
The Valor model 530 heater with the 539 or 550 Cast Arch Fronts comes ready for installation as a zero clearance
unit into combustible type framing, without need for a separate zero clearance kit. The 530 installed without the
standard zero clearance stand-off spacers may also be installed into existing solid-fuel burning fireplaces provided
space and local codes permit.
Hearth Requirements
All installations will require a hearth or floor, flush with the bottom of the heater, to support the weight of the cast iron
plate and to ensure the removable hearth fender rests at the proper height.
A non-combustible hearth is not required in front of this appliance.
Floor Requirements
The 530 heater is approved for installation directly on any combustible material other than soft flooring material
such as carpet or vinyl.

Mantel Requirements

The Arch Fronts series is designed to install with combustible mantels provided clearances are maintained as
indicated in the Dimensions and Clearances, and Framing diagrams below and on the following page. The 539 and
the 550 back plate may also be installed without a mantel provided listed clearances are maintained. Be aware that
although safe, some combustible materials and finishes at the listed clearances may, over time, discolor, warp, or
show cracks. Care should be taken when choosing materials—consult your fireplace dealer.
with 530 Firebox Engine
Dimensions & Clearances—539 and 550 Arch
fronts (539 Windsor Arch shown here)
3