Dimensions & Clearances to Combustibles
inches [mm]
27-1/4 [691]
x
Gas line
connection
point
Hinged control
access door
26-11/16 [678]
Front View
Casting Tolerances
Due to the nature of cast iron and concrete, dimen-
sional consistency may vary from one unit to the next
and some variation in surface finish and flat-ness is
to be expected. We have done our best to control
and make allowance for this; however some variation
is inevitable.
Floor Requirements
When the appliance is installed directly on carpeting,
tile or other combustible material other than wood
flooring, the appliance shall be installed on a metal or
wood panel extending the full width and depth of the
appliance.
Mobile Home Floor Fixing
The Madrona stove must be fixed to the floor
through the floor when used in a mobile home.
Mantel Requirements
The Madrona stove may be installed with a
combustible mantel provided clearances are
maintained as indicated above. Be aware that
although safe, some combustible materials and
finishes at the listed clearances may, over time,
discolor, warp, or show cracks. Care should be taken
when choosing materials—consult your fireplace
dealer.
A
Mantel
B
x
14-3/4 [374]
16-1/4 [413]
Right Side View
Corner Dimensions
Alcove Clearances
Mantel / shelf clearances
Mantel
0–1
Depth 'A'
[0–26]
Mantel
34
Height 'B'
[864]
Ø 6-5/8"
venting
1 [26]
4-5/8 [118]
minimum
Centre of vent
Gas line connection point
3/8" NPT FEMALE at valve
Gas line access
point 10 [254]
Minimum 61-1/8" (1553 mm)
31-1/4" [794 mm] minimum
inches [mm]
2–5
6–18
19–24
[51–127]
[152–457]
[483–610]
36
38
42
[914]
[965]
[1067]
Suggested gas line
access point through wall.
Route to avoid optional fan.
10 [254]
Ø 6-5/8"
venting
Pipe supplied
with engine
(see engine
manual)
x
x
2 [52]
minimum
Sidewall
Top View
90°
Zero clearance
Front surface
of stove
26" [660 mm]
maximum
3