Kit Contents
1 Front Casting Assembly
1 Top Baf e
1 Rear Base Support
1 ZC stand-off RH
1 Pack of Screws
Casting Tolerances
Due to the nature of cast iron, dimensional consistency
may vary from one unit to the next and some variation
in surface nish and atness is to be expected. We
have done our best to control and make allowance for
this; however some variation is inevitable.
Applications
The Valor model 530 heater with the 536CXB President
ZC Cast Front comes ready for installation as a zero
clearance unit into combustible type framing, without
need for a separate zero clearance kit. The 530
installed without the standard zero clearance stand-off
spacers may also be installed into existing solid-fuel
burning replaces provided space and local codes
permit.
Hearth Requirements
A 7/8”" high plinth is supplied to raise the heater and
ensure a base at the proper height for the cast front to
sit on regardless of oor nish height. If not using the
plinth supplied, you MUST make allowance for oor
nish and raise (shim) the heater up so the bottom
of the heater sits at the nished oor/hearth height,
otherwise, the cast front will not sit at the proper height.
A non-combustible hearth is not required in front of this
appliance.
2
Top Baffle
Barrier Screen
Front Casting
Insulation
Rear Base
Support
Plinth
Floor Requirements
The 530 heater is approved for installation directly
on any combustible material other than soft ooring
material such as carpet or vinyl.
Mantel Requirements
The 536CXB President ZC Cast Front may be installed
with a combustible mantel provided clearances
are maintained as indicated in the Dimensions and
Clearances below and in the Framing diagrams on
the following pages. Be aware that although safe,
some combustible materials and nishes at the
listed clearances may, over time, discolor, warp, or
show cracks. Care should be taken when choosing
materials—-consult your replace dealer.
Stand-offs (2)
Framing Plate
w/Brackets