Periodic Checks Performed Following Maintenance Operations; First Radio Remote Control Startup - Jay Electronique UC Notice Technique D'installation Et D'utilisation

Télécommandes radio industrielles
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.1.1- Periodic checks and checks performed following
maintenance operations
In addition to the commissioning checks which should be performed, also check :
- That the ergonomic features of the transmitter unit have been preserved, such
as: pressure on function buttons, emergency stop button pushed in correctly,
etc...
- Response time of commands between transmission of a command and resulting
movement.

6.2- First radio remote control startup

1-
Switch ON the UCR receiver.
2-
Plug the UWB battery pack into UCE transmitter housing.
3-
Install the electronic key on the transmitter.
4-
Copy electronic key identity code in UCE transmitter, see procedure on § 6.3.4.
5-
Unlock the transmitter stop palmswitch button.
6-
Press the «On/Horn» button until the receiver is started up. (safety relays are
activated).
To stop the radio remote control : press the transmitter stop palmswitch button.
NB : If this procedure is not observed the transmitter indicates an error of the
type 3 flickerings (repeat procedure described on §6.3.4) or 5 flickerings
(error of stop or startup) of its red and green indicator lights.