Uce Transmitter Indicator Light Functions; Error Messages - Jay Electronique UC Notice Technique D'installation Et D'utilisation

Télécommandes radio industrielles
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.3.5- UCE transmitter indicator light functions

- Error messages

Transmitter state
(The transmitter stop
palmswitch is unlocked)
During attempt to program
«Standby»
"Dead man" duration or
radio channel or when
attempting to copy the
identity code
Before or after "On/horn"
button is pressed
Before "On/horn" button is
pressed
After "On/horn" button is
pressed
Before "On/horn" button is
pressed
Before or after "On/horn"
button is pressed
Before "On/horn" button is
pressed
Before "On/horn" button is
pressed
Before "On/horn" button is
pressed
Before "On/horn" button is
pressed
FR
- 8 8 -
Red indicator
light
indicator light
Alternate flashing Alternate flashing
ON
Flashes 2 times
Flashes 2 times
Flashes 2 times
Flashes 2 times
Flashes 3 times
Flashes 3 times
Flashes 4 times
Flashes 4 times
Flashes 5 times
Flashes 5 times
Flashes 6 times
Flashes 6 times
Flashes 7 times
Flashes 7 times
Flashes 8 times
Flashes 8 times
EN
DE
Function or corresponding
Green
Transmitter is locked.
Programming is required, see procedure in
§6.3.1 of UC technical manual.
No electronic key
ON
Install electronic key on tranmitter before
powering up the transmitter
Electronic key is not valid
The electronic key is incompatible with the
UCE
Electronic key is removed from the UCE
when transmitter is powered up
Identity code error
Mismatch detected between electronic key and
UCE memory.
Reprogramming is required, see procedure in
§6.3.4 of UC technical manual
-One or several function buttons are
defective
Or
-The button configuration is different from
that contained in the electronic and the
physical configuration on the transmitter
-Stop or start up error detected
Be sure to observe start up conditions specified
in §6.2 of UC technical manual
Or
-Transmitter stop palmswitch button faulty
-Stop or start up error detected
Be sure to observe start up conditions specified
in §6.2 of UC technical manual
Or
-Transmitter stop palmswitch button faulty
Internal electronic key error
Internal UCE transmitter error
message
UC 323882G

Publicité

Table des Matières
loading

Table des Matières