4.1.3- «Standby» function
The «standby» safety function deactivates the remote control (radio transmission
cut off) when the transmitter function buttons have not been actuated for a
duration of N minutes.
The N parameter is user-configurable and can take the values 01 to 98 minutes.
On delivery, the duration is defined for 4 minutes.
- If N value is configured to 99 minutes, the transmitter considers that the
standby duration is infinite (until the battery pack is entirely discharged)
Restarting the transmitter after the «Standby» function has been activated :
- Press the stop palmswitch button on the transmitter.
- Unlock the stop palmswitch button on the transmitter.
- Press the green «On/Horn» button.
Changing the «standby» duration: :
The standby duration N can be modified by a trained operator by performing the
procedure described in § 6.3.3.
NB:
The duration is stored in the UCE transmitter electronic key.