Jay Electronique UC Notice Technique D'installation Et D'utilisation page 71

Télécommandes radio industrielles
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- Characteristics of the «Horn» relay and «control» relays
The «Horn» relay is active when the transmitter «On/Horn» button is pressed.
This relay isn't auto-maintained.
«Control» relays are active when transmitter function buttons are pressed.
• Contacts : AgNi 0,15
• Maximum power at cosphi=1 : 2000 VA
• Maximum current switching : 8 A
• Maximum voltage switching : 400 VAC
• Minimum current / voltage advised switching : 100 mA / 12 VDC
• 100 000 switching cycles at 250 VAC, 8 A, cosphi=1
• 50 000 switching cycles at 24 VDC, 8 A
• Tests per EN 60947-5-1 :
DC13 à 0,5 A / 24 VDC
AC15 à 3 A / 250VAC
- Number of switching cycles on various contactors
Contactor
Switching at 230VAC (70VA,cosphi=0,75)
CA2DN
LC1D09
Switching at 110VAC, (70VA,cosphi=0,75)
LC1D18
LC2D09
Switching at 48VAC (70VA,cosphi=0,75)
UC 323882G
Physical unit switched by relay
Number of switching
Safety
relays
2 x 10
1 x 10
0,5 x 10
DE
EN
cycles
"Horn" relay
and
"Control"
relays
6
6
2 x 10
6
6
1 x 10
6
6
0,5 x 10
FR
-71-

Publicité

Table des Matières
loading

Table des Matières