Applicable to
Assembling the actuator
Fig. 34: Assembling the actuator
Assembling the limit switch
Fig. 35: Assembling the limit switch
26.03.2019
Version
Size
Personal:
Schutzausrüstung:
Prerequisite:
n
The electric gear unit and/or motor (if available) are secured
against restarting.
1.
Place the actuator (Fig. 34/2) at the height of the holes below
the guide carriage (Fig. 34/3).
2.
Tighten 2 screws (Fig. 34/1):
Size
60, 80, 120 M4
3.
Insert and position the slot stones (Fig. 35/1) in the slot of the
guide profile.
4.
Place the limit switch (Fig. 35/4) along with a holding plate
(Fig. 35/3) at the height of the inserted slot stones.
5.
Tighten 2 screws (Fig. 35/2).
Size
60, 80
120
ð The limit switch is assembled.
Linear unit RK MonoLine R/RK MonoLine Z
Assembling optional modules > Assembling the limit switch
RK MonoLine R, Z
60/80/120
n
Assembly staff
n
Protective clothing
n
Protective gloves
Safety shoes
n
Screw size
Screw size
M5
M5
Assembly
Tightening torque [Nm]
2
Tightening torque [Nm]
4
5.9
105