Beretta Mynute S 24 C.S.I. Manuel D'utilisation Et D'installation page 16

Masquer les pouces Voir aussi pour Mynute S 24 C.S.I.:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
ENGLISH
DESCRIPTION
DHW operation
Maximum pressure
Minimum pressure
Hot water quantity with ∆t 25°C
with ∆t 30°C
with ∆t 35°C
DHW minimum output
Selection field of DHW temperature
Flow regulator
Gas pressure
Methane gas nominal pressure (G20)
LPG liquid gas nominal pressure (G30)
LPG liquid gas nominal pressure (G31)
Hydraulic connections
Heating input - output
DHW input-output
Water tank delivery - output
Gas input
Boiler dimensions
Height
Width
Depth of housing
Boiler weight
Flow rate (G20)
Air capacity
Flue gas capacity
Mass flow of flue gas (max-min)
Flow rate (G30)
Air capacity
Flue gas capacity
Mass flow of flue gas (max-min)
Flow rate (G31)
Air capacity
Flue gas capacity
Mass flow of flue gas (max-min)
Fan performance
Residual head of boiler without pipes
Concentric flue gas discharge pipes
Diameter
Maximum length
Drop due to insertion of a 45°/90° bend
Hole in wall (diameter)
Separate flue gas discharge pipes
Diameter
Maximum length
Losses for a 45°/90° bend
Installation B22P–B52P
Diameter
Maximum length of drainage pipe
Flue gas exhaust pipes
Diameter
NOx class
Emission values at max. and min. rate of gas G20*
Maximum - Minimum
CO s.a. less than
CO
2
NOx s.a. lower than
Flue gas temperature
* C.A.I. models: check performed with pipe ø 130 (24 C.A.I. E) - ø 140 (28 C.A.I. E), length 0,5m - water temperature 80-60°C
C.S.I. models: check performed with concentric pipe ø 60-100, length 0,85m - water temperature 80-60°C
16
Mynute S 24 C.A.I. E Mynute S 28 C.A.I. E Mynute S 28 R.S.I.
bar
6
bar
0,15
l/min
13,7
l/min
11,5
l/min
9,8
l/min
2
°C
37/60
l/min
10
mbar
20
mbar
28-30
mbar
37
Ø
3/4"
Ø
1/2"
Ø
-
Ø
3/4"
mm
740
mm
400
mm
332
kg
30
Nm
h
44,666
3/
Nm
3
/h
47,345
gr/s
16,115-15,926
Nm
h
43,235
3/
Nm
3
/h
44,020
gr/s
15,033-14,182
Nm
h
44,620
3/
Nm
3
/h
45,655
gr/s
15,589 -15,004
Pa
-
mm
-
m
-
m
-
mm
-
mm
-
m
-
m
-
mm
-
m
-
mm
130
2
ppm
80-60
%
6,7-2,7
ppm
160-110
°C
138-96
6
-
0,15
-
16,5
-
13,7
-
11,8
-
2
-
37/60
-
12
-
20
20
28-30
28-30
37
37
3/4"
3/4"
1/2"
-
-
3/4"
3/4"
3/4"
740
740
450
400
332
332
32
32
50,960
45,899
54,160
48,907
18,855 -16,978
16,59-17,98
48,088
43,539
50,432
45,738
17,868-15,833
16,20-17,23
49,811
44,449
52,285
46,767
18,484-16,423
16,52-17,59
-
150
-
60-100
-
3,40
-
1 - 1,5
-
105
-
80
-
14,5+14,5
-
1,2 - 1,7
-
80
-
20
140
-
2
3
90-20
100-120
6,7-3,1
7,4-2,9
170-80
140-40
132-97
139-112
Mynute S 35 R.S.I.
-
-
-
-
-
-
-
-
20
-
37
3/4"
-
3/4"
3/4"
780
505
328
39
59,357
63,129
21,431-23,549
-
-
-
58,957
60,415
20,578-23,206
110
60-100
2,30
1 - 1,5
105
80
8+8
1,2 - 1,7
80
12
-
3
100-200
7,1-2,2
140-100
148-113