W3: Trimmer Imax; Pk: Key Error; Nl: Input Voltage Error; Vs: Voltage Selector Error - DAB AQUATWIN TOP 132 Instructions Pour L'installation Et La Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH

- W3: Trimmer Imax

This error appears if the trimmer Imax inside the panel has been moved. You are asked whether to accept or ignore the new value of Imax. If it is
accepted, the value of the dip switches will also be accepted.

- PK: Key error

If pressing of the buttons on the front board is detected in the first 30 seconds of power supply, the buttons incoherence alarm is activated.
Check that the buttons function efficiently!

- NL: Input voltage error

If the alternating input voltage of the panel is not within the limits established in the specifications, the input voltage alarm is given. The alarm is
deactivated one minute after the alternating input voltage returns within the limits. If this error appears, check that the supply voltage is within
the limits accepted by the E.Box panel, see table 1 - Technical Data.

- VS: Voltage selector error

This error may occur on the E.Box plus, in the case of a fault of the E.Box Plus or breakage of the fuse FU2. In the case of an alarm, check the
fuse FU2 and ensure the panel is supplied with an adequate voltage, as specified in Table 1 – Technical Data.
- V0..V15: Voltage error
If the electronic board has a fault that takes one of its internal voltages to unacceptable levels, the alarm is activated for panel internal voltage
error V0..V15. This error cannot be reset. The code Vx indicates the part of the circuit where the malfunction was found. If this error appears,
check the supply voltages and the wiring. If everything is in order, the E.Box has suffered internal damage and must be repaired.

- OM: Changed operating mode

This message is only a warning and is not an error. It appears only in the alarm log and indicates that the configuration of the E.Box has been
changed, for example from drainage to pressure boosting.
- E0..E15: Internal error
Panel internal error. This error cannot be reset. If this error appears, check the supply voltages and the wiring. If everything is in order, the E.Box
has suffered internal damage and must be repaired.
54

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquatwin top 40/50Aquatwin top 40/80

Table des Matières