Programming Sequence - Erreka VIVO-D201 Manuel De L'installateur

Armoire de commande pour portes battantes avec encodeur
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

STARTING UP AND PROGRAMMING
3

PROGRAMMING SEQUENCE

Display
?
ENTER
á
or
à
CL
It is necessary to close the gate or disconnect and
reconnect the control board in order to access the
programming menus.
Press the ENTER button to access the programming
menus. The display shows "C"flashing.
The ^ and
keys can be used to select the required
V
values, which should be confirmed by pressing
ENTER. Pressing ENTER will confirm the value and
move onto the next display.
Use ESC to go back to the previous display.
To leave the programming menu, press ESC several
times until the display shows CL.
Initial Conditions Programming (D1= "C")
D1 D2 Parameter
C
0
Number of operators
1
Motor 1 turning direction
2
Motor 2 turning direction
3
Type of operator
4
I n t e r i o r s a f e t y d e v i c e
(photocell)
5
E x t e r i o r s a f e t y d e v i c e
(photocell)
6
Electrolock / electromagnet
7
Encoder / Limit switches
8
Radio receiver
9
Safety strip
60
Installation Manual
General navigation through the programming parameters and menus
D1
C
ESC
Select the value
using ^ and
V
D3
0
0
0
0
0,1
0,1
0
0
0
0
D2
ENTER
á
1
ESC
à
Select the value
using ^ and
V
All the programmable functions are organised in four
menus, which must be programmed in the following order:
1 Initial Conditions menu (D1=C, page 60), where
the installation characteristics are defined (number
of operators, turning direction, etc).
2 Programming menu (D1=P, page
programme the radio codes and the gate open/
close.
3 Main Functions menu (D1=F, page 62), to select
operation mode, standby time and pedestrian
opening.
4 Advanced Functions menu (D1=A, page 63).
Pre-
D4
determined
Options
option
1, 2
02
01: one operator, 02: two operators
1, 2
01
01: direction A, 02: direction B
1, 2
01
01: direction A, 02: direction B
1...5
01
01: BUL, 02: TOPO, 03: ARC 24V, 04: ARES
24V, 05: AXIL 24V
0,1
00
00: not installed,10: no testing,11: with testing
0,1
00
00: not installed,10: no testing,11: with testing
0...4
00
00: not installed
01: electrolock without reverse impulse
02: electrolock with reverse impulse
03: electromagnet without reverse impulse
04: drop electromagnet (activated 0.5 seconds
before the operation starts)
0
01
00: not installed
01: with encoder
02: with limit switches
03: with dual encoder
04: with encoder and limit switches
1
01
01: fixed code (trinary)
1,2
01
01: mechanical strip, 02: resistive strip
D3 - D4
ENTER
á
0 X
ENTER
(confirming)
à
Select the value using
^ and
ESC
(unconfirmed)
à
V
61), to

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vivo-d201 m

Table des Matières