1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
C flashing. Press ENTER to confirm.
D2 flashes.
If "motor turning direction" has been selected
(D2=1 or D2=2), turning direction can be checked
by pressing ST1 and ST2 whilst D2 flashes. ST1
should produce opening and ST2 closing. If it does
not, modify parameter D4.
Radio code programming (with RSD only) for total opening ("P1") and pedestrian
opening ("P2")
The radio code programming described below is
only valid if the RSD plug-in receiver has been
installed. If a different receiver is used, programme
the radio code as described in the corresponding
instructions.
D1
D2
D3
D4
P
1
O
ç
2
O
ç
Programming the gate run ("P3"), operators with encoder
O
Before programming the gate open/close,
ensure the turning direction of the operator is
correct (see "Initial Conditions Programming
(D1= "C")" on page 60).
D1
D2
D3
D4
P
3
O
ç
until D1 shows the letter
V
T o t a l o p e n i n g r a d i o
programming (code and
channel)
Pedestrian opening radio
programming (code and
channel)
Programming the gate run
STARTING UP AND PROGRAMMING
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to
confirm.
5 Press ESC to return to the previous display.
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
P flashing.
Press ENTER to confirm. D2 flashes.
3 Press the buttons ^ and V until the required D2
parameter appears (P1 to programme the code for
total opening; P2 to programme the code for
pedestrian opening).
Press ENTER to confirm. D3 and D4 flash.
4 Whilst Oç flashes, press the transmitter button. If the
code is correctly programmed, D3-D4 stop flashing
(remain static) and D2 flashes.
5 Press ESC to return to the previous display.
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
flashing.
Press ENTER to confirm. D2 flashes.
3 Press the buttons ^ and V until the required D2
parameter appears (D2=3).
4 Press ENTER. The gate carries out a reset and then
programmes the opening and closing runs (Oç
flashes in the display).
5 Wait whilst the gate carries out the open/close.
When programming is finished, D3-D4 stop flashing
(remain static) and D2 flashes.
6 Press ESC to return to the previous display.
until the required D2
V
until the required D3 and
V
until D1 shows the letter
V
until D1 shows the letter P