Advanced Functions Programming (D1= "A")
D1 D2
Parameter
A
0
Flashing light
1
Garage light time
2
Gate speed
3
Slowdown speed
4
Slowdown distance
5
Recede after closing
(ensures the operator
does not get stuck on
the stopper)
6
Maximum thrust
7
Interior or exterior
photocell used during
standby (in automatic
mode only)
Pushbutton operation
8
during standby (in
automatic mode only)
9
Opening mode
A
Lapse between leaves in
closing (the lapse in
o p e n i n g i s a n o n -
adjustable fixed value)
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
A flashing. Press ENTER to confirm. D2 flashes.
Pre-
D3
D4
determined
option
0
1...4
0..5.
0...9
0
1...9
0
1...9
0
0...5
0
0...5
0...1
0...6
0
0...2
0
0...2
0
1
0
2
0
3
0
0...9
until D1 shows the letter
V
STARTING UP AND PROGRAMMING
Options or values
01
01: voltage free output, constant, without pre-
warning
02: voltage free output, constant, with pre-
warning
03: voltage free output, intermittent, without
pre-warning
04: voltage free output, intermittent, with pre-
warning
03
59 = 59 sec; 2.5 = 2 min. 50 sec., etc
05
01: minimum speed,..., 09: maximum speed
05
01: minimum speed,..., 09: maximum speed
03
00: minimum distance; 05: maximum distance
00
00: without receding,...,
05: maximum recede
03
01: minimum thrust; 06: maximum thrust
00
00: does not affect standby time
01: immediate close when the photocells are
released
02: restarts standby time
02
00: has no effect during standby
01: produces closing after 3 seconds
02: restarts standby time
F101: automatic closing, collective opening (a key
x
command during opening does not halt the gate)
F102: step-by-step closing, step-by-step
opening: during opening, a key command halts
the gate, and a new command closes the gate
F101: automatic closing, step-by-step
opening: during opening, a key command halts
the gate, and a new command closes the gate
F102: step-by-step closing, collective
opening (does not obey the key commands
during opening)
F101: automatic closing, opening with
alternative shutdown: during opening a key
command halts the gate, and subsequent
closing is carried out automatically
F102: step-by-step closing, step-by-step
opening: during opening, a key command halts
the gate, and a new command closes the gate
01
00: no lapse in opening or closing (apply only in
gateswithout overlap);
01: minimum lapse (approximately 1 second); ... ;
09: maximum lapse (approximately 9 seconds)
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to confirm.
5 Press ESC to return to the previous display.
until the required D2
V
until the required D3 and
V